Heat & Glo LifeStyle PIER-36TRLP-IPI Burner User Manual


 
Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/1120
C
A
B
D
Figure 5.3 Clearances to Combustibles PIER-36TR-IPI
G
F
I
I
E
H
* Adjust framing dimensions for interior sheathing (such as sheetrock)
PIER-36TR-IPI
ABCDEFGHI
DVP Pipe SLP Pipe
Rough
Opening
(Height)
DVP Pipe*
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Ends of
Appliance
Sides of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Rough
Opening
(Depth)
Inches
10 8-5/8 38-1/8 23 40 31-5/8 0 0 1/2 36
Millimeters
254 219 968 584 1046 803 0 0 13 914