Heat & Glo LifeStyle 6000TRS-CE Indoor Fireplace User Manual


 
Heat & Glo • 6000TRS-CE • 2049-900 Rev. Q • 2/1122
Figure 17. Installing Support Brackets
3. Install Firestops
For Horizontal Runs - Firestops are REQUIRED on
both sides of a combustible wall through which the
ue passes.
To install restops (heat shield) for horizontal runs that
pass through either interior or exterior walls:
• Cut a 25,4 cm X 30,5 cm hole through the wall.
• Position the restops on both sides of the hole
previously cut and secure the restops with nails or
screws.
• The pipe opening of the restops MUST BE placed
towards the bottom of the restop.
• Continue the ue run through the restop.
WALL BRACKET
WALL STUD
FLUE
OUTLET
2,5 cm
MINIMUM
2,4 m
For Vertical Runs - The flue system must be
supported every 240 cm above the heater ue outlet
by wall brackets.
To install support brackets for vertical runs:
• Attach wall brackets to the ue pipe and secure the
wall bracket to the framing members with nails or
screws.