Heat & Glo LifeStyle 6000TRS-CE Indoor Fireplace User Manual


 
Heat & Glo • 6000TRS-CE • 2049-900 Rev. Q • 2/1120
WARNING: THE REAR FLUE COLLAR SEAL
CAP MUST REMAIN ATTACHED TO THE REAR
FLUE COLLARS IF THE FLUE SYSTEM IS AT-
TACHED TO THE TOP STARTING COLLARS.
SEE FIGURE 15.
Figure 15
B. Installing Flue Components
After determining which set of starting collars will be used
(top or rear), follow venting instructions accordingly.
Venting Out the Rear Flue
Remove the installed rear seal cap from the rear starting
collars by cutting the strap at each end (See Figure 15).
Follow the ue con guration tables accordingly.
Remove the 12.7 cm diameter heat shield from the 1.27 cm
diameter collar by sliding it out. Remove insulation piece.
WARNING: FAILURE TO REMOVE INSULA-
TION IN THE SET OF COLLARS YOU ARE
USING COULD CAUSE A FIRE.
WARNING: YOU MUST LEAVE THE INSULA-
TION IN PLACE IN THE SET OF COLLARS YOU
ARE NOT USING.
!
!
!
!
WARNING: THE TOP HEAT SHIELD (INSIDE
THE FIREBOX) MUST REMAIN ATTACHED IF
THE FLUE SYSTEM IS ATTACHED TO THE
REAR STARTING COLLARS. SEE FIGURE 15.
Venting Out the Top Flue
Remove the top ue collar seal cap by cutting the strap on
each end. Remove both pieces of insulation inside the top
two starting collars (see Figure 15).
Remove the 10.2 cm diameter heat shield from the 10.2
cm diameter collar by sliding it out.
You have to take the glass off again for positioning the
logs when the unit is nally installed in place and nished
around it. Reinstall the glass door. Attach ue system to
the top starting collars.
Insert screwdriver
or similar object
here to remove cap.
CUT HERE
Venting
Out Rear
Venting
Out Top
HEAT
SHIELD
DISCARD
INSULATION
SEAL
CAP
SEAL
CAP
HEAT
SHIELD
INSULATION,
DISCARD
BOTH
PIECES