Heat & Glo LifeStyle 6000TRS-CE Indoor Fireplace User Manual


 
Heat & Glo • 6000TRS-CE • 2049-900 Rev. Q • 2/1112
HORIZONTAL
TERMINATION
WALL FIRESTOP
90 DEGREE
ELBOW
VERTICAL
TERMINATION
STORM COLLAR
ROOF FLASHING
HORIZONTAL PIPE
SUPPORT
PIPE LENGTH
WALL BRACKET
CEILING
FIRESTOP
DVP-SERIES
DVP-TRAP
DVP-TVHW
FLUE SYSTEM TERMINATION KITS
Figure 5. Flue Components and Terminations
A. Flue System Approvals
These models have ue starting collars on both the top and
the back of the unit. Depending upon the installation, decide
which ONE set of starting collars will be used to attached the
ue system. The starting collar sealing cap must remain on the
starting collar NOT used.
These models use DVP-series direct ue components when
using the TOP and REAR ue collars.
Approved ue system components are labeled for identi cation.
NO OTHER FLUEING SYSTEMS OR COMPONENTS MAY
BE USED. Detailed installation instructions are included with
each ue termination kit and should be used in conjunction with
this Installers Guide. Figure 4 shows ue system components
and terminations.
Identifying Flue Components
The ue systems installed on this gas replace may include one,
two, or three 90°
elbow assemblies. The relationships of vertical
rise to horizontal run in ue con gurations using 90° elbows
MUST BE strictly
adhered to. The rise to run relationships are shown
in the ueing drawings and tables on the next several pages.
Note: Two 45° elbows may be used in place of one 90° elbow.
You MUST always maintain the MAXIMUM and MINIMUM rise-
to-run ratios in the ue system when using 45° elbows.
Step 3
Installing the
Flue System