Stovax Studio 22 Indoor Fireplace User Manual


 
28
2
AR1936
Oncethehandsethasanewcode,thecontrolboxneedsto
be reprogrammed:
To access the control box, see Servicing Instructions,
Section 7 - Main Control Assembly.
• Pressandholdtheresetbuttononthecontrolboxuntil
you hear two signals. After the second longer signal:
• Releasetheresetbuttonandwithin20seconds:
-PresstheDOWNbuttononthehandsetuntilyour
hear an additional long signal confirming the new code
INSTALLATION INSTRUCTIONS
COMMISSIONING
1. COMMISSIONING
1.1 Complete the Commissioning Checklist at the front of this
manual covering:
• Fluechecks
• Gaschecks
For working pressure test, use the access panel at the gas
connection ensuring the burner is in position, see
Installation, Section 9, 9.1
1.2 In the unlikely event that the appliance is receiving
interference from other electronic devices, re-programme
the handset/Control box
Reprogramming handset/Control box
• Removethebatterycoverfromthehandsettoseethe
four DIP switches. See Diagram 1
1
AR1935
Each of the four switches can be set to either one of two
positions, in any combination.
Tore-codethehandset:
• ChangethecombinationofhowtheDIPswitchesareset.
For example see Diagram 2: