Stovax Studio 22 Indoor Fireplace User Manual


 
20
INSTALLATION INSTRUCTIONS
INSTALLATION
15
AR2134
• Putverticalstudworkatminimumclearancetothesideof
the fire (50mm)
•Securetotheverticalstudworkthroughtheholesinthe
metal brackets fitted to the fire, Diagram 16
Thekithasbeendesignedsothatnon-combustibleboard
can be taken right up to the edge of the four brackets,
Diagram 17
16
AR2133
17
AR2085
Build the studwork chimney breast to the desired size:
• Ensureallclearancestocombustiblematerialare
maintained, Section 3, 3.1 above
• Decideonfluerequirements
• Cutaholefortheflueexit-seeInstallation
Instructions, Flue Assembly
18
AR1902
• Fitnon-combustibleboardtothestudworkaboveandto
the sides of the fire. This should extend a minimum of
400mm above the appliance and a minimum of 50 mm to
each side
• Fitplasterboardtotheremainingchimneybreastfront
• Connectthefluesystemandgasservicesusingthe
opening in the side of the chimney breast for access
After commissioning, finish the sides of the chimney breast,
Diagram 19
19
AR1911
Detail A
A
•Applyaplasterfinishtothechimneybreast