Stovax Studio 22 Indoor Fireplace User Manual


 
18
INSTALLATION INSTRUCTIONS
INSTALLATION
3. STUD WORK INSTALLATION
THERE ARE THREE TYPES OF INSTALLATION INTO
STUDWORK DESCRIBED IN THE FOLLOWING PAGES:
1) FOR STUDIO 22 WITH EITHER THE STEEL, PROFIL
OR BAUHAUS FRAME, SEE SECTION 4
2) FOR AN INSTALLATION WHERE THE STUDIO 22 SITS
FLUSH TO THE FINISHED 'EDGE' OF THE WALL, SEE
SECTION 5
3) FOR A FURTHER 'EDGE' INSTALLATION PROVIDING
A COOL WALL ABOVE THE APPLIANCE TO ALLOW
CUSTOMERS TO HANG PICTURES ETC., SEE SECTION
6
3.1
DISTANCE TO COMBUSTIBLE MATERIAL
COMBUSTIBLE PARTS OF THE STUDWORK MUST BE
KEPT BEYOND THE MINIMUM DIMENSIONS SHOWN
IN DIAGRAM 8. EVEN IF THE FRAMEWORK IS
PROTECTED BY NON-COMBUSTIBLE MATERIAL, YOU
MUST MAINTAIN THESE DIMENSIONS.
8
AR2077
3.2 DO NOT PACK THE VOID AROUND OR ABOVE THE
APPLIANCE WITH INSULATION MATERIALS SUCH AS
MINERAL WOOL.
3.3 THE VOID BUILT FOR THE APPLIANCE MUST BE
VENTILATED TO PREVENT A BUILD-UP OF HEAT. IF THE
VOID IS SEALED, THEN YOU MUST FIT VENTS AT BOTH
LOW AND HIGH LEVELS OF APPROXIMATELY 50CM
2
EACH. THESE VENTS MUST TAKE COLD AIR FROM THE
ROOM AND RETURN WARM AIR BACK INTO THE
ROOM
3.4 AN ACCESS HATCH MUST BE LEFT IN THE SIDE OF THE
CHIMNEY BREAST FOR FUTURE SERVICING AND
INSPECTION OF THE FLUE AND APPLIANCE.
4. STUDWORK INSTALLATION FOR
STUDIO WITH FRAMES
• Buildthestudworkchimneybreastandenclosuresto
the desired size to include the protected platform at the
required height.
•Linetheaperturefortheappliancewith12mmthicknon-
combustible material as shown, Diagram 9
9
AR1902
• Ensuretheclearancesaremaintained,seeDiagram8
• Sitetheapplianceanddecideonfluerequirements
• Cutaholefortheflueexit-seeInstallation
Instructions, Flue Assembly
• Providegasservicesintotheappliancevoidontheleft-
hand side
Because no combustible material can be used above the
fire, we provide a support bar:
• Markoutthepositiontofitthesuppliedtopsupportbar
into the studwork at the correct height. This bar needs to be
recessed into the studwork, Diagram 10
10
AR1903
Detail A