First Alert FA168CPSSIA Home Security System User Manual


 
– 9 –
66
Arm Away/Stay Rpt Code
See above for entries.
[0,0,0,0,0,0]
Away Stay Away Stay Away Stay
Part. 1 Part. 2 Common
This option allows for independent programming of Away and Stay
reports for each partition, including the common lobby.
NOTE: “OPEN” reports are not sent if the associated closing report is
not enabled.
67
RF Trans. Low Bat Report Code
See above for entries.
| [00]
Sent when a transmitter low-battery condition exists.
UL: must be enabled if wireless devices are used
68
Cancel Report Code
See above for entries.
SIA-Compliant Controls: [10]
Report enabled.
| [00]
Sent upon disarming the system after an alarm condition was reported.
69
Recent Closing Report Code
Not applicable to FA148CP/FA168CPS
See above for entries.
SIA-Compliant Controls:
Always enabled.
| [11]
SIA-Compliant Controls: Field does not apply to other controls.
Similar to the Exit Error condition described in field *59, but occurs if
any burglary zone is faulted within two minutes after the initial exit
delay expires. Disarming the system within the two minutes stops the
alarm sound and displays "ALARM CANCELED " or "CA" and faulted
zone number. No message is sent to the Central Monitoring Station.
If the system is not disarmed within two minutes, the alarm sound
continues and a “recent closing” and a “zone alarm” message are
sent to the Central Monitoring Station (after dial delay expires).
RESTORE REPORT CODES (
70 –
76)
70
Alarm Restore Rpt Code
See above for entries.
[0]
Alarm restore signals indicate that respective alarm zone(s) are no
longer faulted. Alarm restore reports are sent to the central station at
bell timeout (field *33), if the zone(s) in alarm are actually restored to a
non-faulted state at that time. Otherwise, alarm restore report(s) for
respective alarm zones are sent when the system is disarmed.
See UL System Reporting Note above *59.
If Reports Per Armed Period Per Zone (*93) is also programmed, the
system will report alarm and restore codes as described above until the
“Reports Per Armed Period” count is reached. Disarming and rearming
will reset the “Reports Per Armed Period” count.
71
Trouble Restore Rpt Code
See above for entries
| [00]
Sent when a trouble in a zone is restored and code + OFF performed.
See UL System Reporting Note above *59.
72
Bypass Restore Rpt Code
See above for entries.
| [00]
Sent when a zone that has been bypassed is unbypassed.
See UL System Reporting Note above *59.
73
AC Restore Rpt Code
See above for entries.
| [00]
Sent after AC power has been restored after an AC power outage.
See UL System Reporting Note above *59.
74
Low Bat Restore Rpt Code
See above for entries.
| [00]
Sent after a system low-battery condition is restored to normal.
See UL System Reporting Note above *59.
75
RF Trans. Lo Bat Rst Rpt Code
See above for entries.
| [00]
Sent when a transmitter’s low battery condition is restored (i.e., new
battery installed).
UL: must be enabled if wireless devices are used. See UL System Reporting
Note above *59.
76
Test Restore Rpt Code
See above for entries.
| [00]
This is sent when the Test mode is exited or upon timeout (4hrs).
See UL System Reporting Note above *59.