First Alert FA168CPSSIA Home Security System User Manual


 
22
XMIT TO CONFIRM
PRESS TO SKIP
Confirm
[] to continue
If “Yes” was entered at the SET TO CONFIRM? prompt
previously (see first prompt following entry into the 58
Expert Programming Mode), the display on the left will
appear. Confirm serial and loop numbers by activating the
wireless key.
IMPORTANT:
When confirmed, the key is not active for arming/disarming until
it is assigned to a user number (using the assigning attributes
command, attribute “4”). See
System Operation
section for
procedure.
Entd A022-4063
Rcvd A022-4064
Not Confirmed
[] to continue
If the serial number transmitted does not match the serial
number entered, a display similar to the one shown will appear.
If the loop number does not match, it will also be displayed.
If so, activate the button on the wireless key once again. If a
match is not obtained (i.e., summary display does not appear),
press the [#] key and then enter the correct serial number.
If the serial number transmitted matches the serial number
entered, the keypad will beep 3 times and will return you to the
Zone Number prompt to enter the starting zone for the next
wireless key.
Or you can return to *58 Menu mode by pressing 00 at the Zone
Number prompt.
NOTE: Following the successful enrollment of each wireless
device, remove ONE of the serial number labels from the device
and affix it in the appropriate column on the ZONE
PROGRAMMING worksheet of the Programming Form; then
enter the other information (zone number, zone type, loop
number, etc.) relevant to that device.
Wireless Key Predefined Default Templates
YOU MUST
PROGRAM
THIS BUTTON
LOOP 4
LOOP 3
ENROLL AS "BR"
LOOP 1
LOOP 2
ON
OFF
5804-001-V1
5804 Wireless Key Transmitter
Note:
These transmitters
are not intended for
use in UL
installations.
LOOP 3
LOOP 1
LOOP 2
LOOP 4
(YOU MUST
PROGRAM
THIS BUTTON)
RED/YELLOW
LED
GREEN/YELLOW
LED
ENROLL AS "BR"
5804BD-007-V0
5804BD 2-Way Wireless Key
Transmitter
For 5804
For 5804BD
TEMPLATE 1 Loop Function Zone Type TEMPLATE 4 Loop Function Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 No Response 23
3 Arm Away 21 3 Arm Away 21
4 No Response 23 4 Disarm 22
TEMPLATE 2 Loop Function Zone Type TEMPLATE 5 Loop Function Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 Arm Stay 20
3 Arm Away 21 3 Arm Away 21
4 Arm Stay 20 4 Disarm 22
TEMPLATE 3 Loop Function Zone Type TEMPLATE 6 Loop Function Zone Type
1 24-hour audible 7 1 24-hour audible 7
2 Disarm 22 2 Arm Stay 20
3 Arm Away 21 3 Arm Away 21
4 Arm Stay 20 4 Disarm 22