First Alert FA168CPSSIA Home Security System User Manual


 
28
01 Delete Zone?
0 = No 1 = Yes 0
Deleting a Zone
0 = don’t delete zones
1 = go to next prompt to
delete zones
[] to continue
To save the zone list, enter 0 and the system returns to the Zone
List No. prompt.
To delete a zone or zones in a zone list, enter 1 to continue.
01 Zn to Delete?
(00 = Quit) 00
Delete the Zone
01-64
= zones to be
deleted from list
followed by [] to
accept each zone
00 to continue
Enter each zone to be deleted from the list, followed by [
]. After
all zones to be deleted are entered, enter 00 to return to the
Zone List No. prompt so that another list can be programmed, if
desired.
† FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56.
82 ALPHA DESCRIPTOR MENU MODE
The system lets you assign zone descriptors for protection zones, keypad panics, and RF receiver supervision faults. Each
description can be composed of a combination of up to 3 words selected from a vocabulary of words stored in memory (see
Alpha Vocabulary List page). In addition, up to 10 installer-defined words can be added to those already in memory, plus 3
additional words can be assigned as partition descriptors. Thus, when an alarm or trouble occurs in a zone, an appropriate
description for that zone's location can be displayed at the keypad. Zone descriptors are recommended for systems using Alpha
display keypads, and are necessary if a 4286 Phone Module is used.
NOTE: You can also enter zone descriptors when the zone is being defined in
56 Menu mode.
4286 NOTE: If using a 4286 Phone Module, select from those words in the Alpha Vocabulary List shown in boldface type.
The phone module will not provide annunciation of the other words.
If a Phone Module is added to an existing system, the Alpha descriptors presently in the system should be reprogrammed,
selecting from those words shown in boldface type in the Alpha Vocabulary List. The phone module will not provide
annunciation of any other words.
82 Menu Mode
Program Alpha ?
0=No, 1=Yes 00
Program Alpha
0 = no (quit Alpha mode)
1 = yes
[] to continue
The “Program Alpha ?” prompt will appear. Press 1 to continue.
Custom Words ?
0=No, 1=Yes 00
Custom Words
0 = no
1 = yes
The “Custom Words” prompt will appear.
Press 0 to program standard alpha descriptors from the fixed
vocabulary. The system then automatically displays the descriptor
for zone 1.
Press 1 to define custom words (see “Adding Custom Words”).
ZN 01
Summary Screen
[] to continue to edit mode
[#] = return to Program
Alpha prompt (to quit)
Note that this is a “Summary mode,” and that no entries can be
made. Entries can be made only when the display contains a
flashing cursor, which signifies Edit mode.”
To exit the Alpha Descriptor mode, press
+ 0 + 0 at the
summary display.
ZN 01
Edit Mode Flashing
Cursor
to edit = zone number then
[], then zone
number again
6 = save word and go to
next word in a
descriptor
8 = save descriptor and go
to next zone
[#] = return to Program
Alpha prompt (to quit)
Descriptor screen for zone 1 appears. To program a descriptor
(up to 3 words) for a zone, do the following:
1. Enter the desired zone number (existing descriptor, if any, is
displayed) and press [], then enter the zone number again to
start edit mode (flashing cursor appears).
2. a. Press [#] plus the 3-digit number from the Alpha Vocabulary
List for the first word.
b. Press [6] to accept the word and move the cursor for the next
word in the descriptor.
3. Repeat steps 2a and 2b for the second and third words (if used).
4. When all words for that descriptor have been entered, press [8]
to save the descriptor for that zone. The summary screen
displays for that zone and the flashing cursor disappears.
5. Press [] at the summary screen and repeat steps 1-4 to
assign a descriptor for the next zone.
6. When all descriptors have been entered, press [#]) at the last
descriptor summary screen to return to the PROGRAM
ALPHA? prompt. Enter 0 (no) at the prompt to exit this mode
and return to Data Field mode.