80 Menu Mode
Output Funct. #
(00 = Quit) 01
Output Function No.
(FA168CPS: 01-48
(FA148CP: 01-24)
[] to continue; 00 to quit
Enter the output function number to be defined (or 00 to exit)
01 A E P Trig
?00 0 0 – ZL=00
Summary Screen
[] to continue
This screen displays a summary of the current output
programming (for this example, Zone List has been selected-this
is the default screen).
A = Output Action; E = Triggering event; P = Partition;
Trig = Trigger type
NOTE: A question mark in the summary screen indicates that the
device number shown has not been mapped. Use *79 Menu
mode to map the device.
01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list (go to “A”)
2 = zone type (go to “B”)
3 = zone number (go to “C”)
[] to continue
Select where the initiating event for this output definition is to
occur as follows:
If you enter “0,” the following prompt appears:
Delete?
0 = NO, 1 = YES
Press 1 to delete this output definition. The system deletes the
output function and any previous programming.
A
01 Zn List
1
Zone List
01-08 = zone list
[] to continue
(prompt appears if zone list was selected)
Enter the desired zone list number associated with this output
number. At the ENTER EVENT prompt, enter the zone list event
that will activate this output
NOTE: Do not use pager zone lists 09-12 in output definitions.
Enter Event 0 = restore; 1 = alarm;
Alarm 1 2 = fault; 3= trouble
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be
restored before the output is restored.
Press [
] to continue and skip to the “Output Action” prompt.
B
01 Enter Zn type
Perimeter 03
Zone Type
See list at right for available
zone types.
(prompt appears if zone type was selected)
Enter the desired zone type associated with this output number.
At the PARTITION prompt, enter the partition in which this zone
type will occur.
CHOICES FOR ZONE TYPES:
00 = Not Used 05 = Day/Night 12 = Monitor Zone
01 = Ent/Exit #1 06 = 24 Hr Silent 14 = Carbon Monoxide††
02 = Ent/Exit #2 07 = 24 Hr Audible 16 = Fire w/verification
03 = Perimeter 08 = 24 Hr Aux 23 = No Alarm Response
04 = Interior Follower 09 = Fire 24 = Silent Burglary
10 = Interior w/Delay 77 = Keyswitch Zone
81 = AAV Monitor Zone
90-91 = Configurable
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay 36 = **At Bell Timeout*** 58 = Duress
21 = Arming–Away 38 = Chime 60 = AAV
22 = Disarming 39 = Any Fire Alarm 61 = AVS/GSMV session begin§
31 = End of Exit Time 40 = Bypassing 62 = AVS/GSMV session end §
32 = Start of Entry Time 41 = **AC Power Failure 66 = Function Key†
33 = Any Burglary Alarm 42 = **System Battery Low 67 = Bell Fail
43 = Comm. Failure 68 = Telco Line Cut
52 = Kissoff 78 = Keyswitch Red LED
54 = Fire Zone Reset 79 = Keyswitch Green LED
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function “07”).
†† when used with an output function, the carbon monoxide zone type
activates upon CO alarms only. Does not activate for trouble conditions.
§ automatically set when appropriate AVS Quick Command performed.
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition 0 = any partition; 1 = partition 1;
Any partition 0 2 = partition 2; 3 = common
Press [
] to continue and skip to the “Output Action” prompt.