First Alert FA168CPSSIA Home Security System User Manual


 
– 11 –
88
Program Mode Lockout Options
0 = standard *98 installer code lockout
(reentry only by [] + [#] within 50
secs after power up)
1 = lockout [] + [#] reentry after *98
exit (reenter via installer code or
downloader only)
2 = not applicable (option doesn’t exist)
3 = lockout local programming after *98
exit (reenter by downloader only)
[0]
This table summarizes the Program Mode Lockout options:
Exit *88 Reentry By:
Command Entry Installer Power-up† Downloader
*99 n/a yes yes yes
*98 0 no yes yes
*98 1 yes no yes
*98 3 no no yes
pressing [] + [#] within 50 seconds of power up
89
Event Log Full Report Code
See box above field *59 for report code
entries.
| [00]
If an Event Logging selection is made in field 90, a message can be
sent to the central station receiver when the log is 80% full. If the log
becomes full, new messages overwrite the oldest messages in the log.
90
Event Log Enables
0 = None
1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore
4 = Bypass/Bypass Restore
8 = Open/Close.
Example:
To select
“Alarm/Alarm Restore”, and
“Open/Close”, enter 9 (1 + 8);
To select all, enter #15.
[3]
This system can record various events in a history log (FA168CPS =
100 events; FA148CP = 50 events). At any time, the downloader
operator can then upload the log and view or print out all or selected
categories of the log. The downloader operator can also clear the log.
Event log can also be viewed at an alpha keypad. The display/printout
at the central station will show the date, time, event, and description of
the occurrences.
Data Entry Example: To select Alarm/Alarm Restore” and
“Open/Close”, enter 9 (1+ 8); to select all events, enter #15.
NOTE
:
System messages are logged when any non-zero entry is made.
91
Option Selection
0 = None
2 = Sounder Delay (delays sounding by
15 seconds)
1 = Bell Supervision Processing†
4 = AAV
8 = Exit Delay Restart/Reset ††
#+12 = AAV and Exit Delay
Restart/Reset
SIA-Compliant Controls:
Options: Same as for
FA148CP/FA148CPS.
Call Waiting Disable:
0 = call waiting not used
1 = call waiting disable digits (*70)
entered in field *40; (when selected,
the system dials the entry in field *40
only on alternate dial attempts; this
allows proper dialing in the event call
waiting service is later canceled by
the user).
[8, 0]
Options SIA-Compliant Controls:
Call Wait Disable
Select the desired options by adding the values of each desired option.
Sounder Delay: If enabled, delays external sounding by 15-seconds.
IMPORTANT: AAV should not be used when Paging or Alarm Reports
are sent to a secondary number unless the monitoring zone option is
used (which pauses calls). Otherwise, the call to the secondary number
by the communicator after the alarm report will prevent the AAV from
taking control of the telephone line, and the AAV “Listen in” session
cannot take place.
UL: must use ADEMCO UVCM module; Exit Delay Restart/Reset must be
disabled
UL: If Sounder Delay used, entry delay (*35) must be 30 sec. max.
SIA Guidelines: Exit Delay should be enabled.
If bell supervision is selected, you must also cut the red PCB Bell Supervision
jumper.
††“Exit Delay Restart/reset” option allows use of the [] key to restart the exit
delay at any time when the system is armed STAY or INSTANT. This feature
also enables automatic exit delay reset, which resets exit delay if the entry/exit
door is re-opened and closed before exit delay time expires after arming AWAY.
Automatic Exit Delay Reset occurs only once during an armed AWAY period.
92
Phone Line Monitor Enable
Entry 1:: 0 = disabled, 1-15 = 1 min - 15
min
(#+10 = 10 min; #+11 = 11 min; #+12 =
12 min;
#+13 = 13 min; #+14 = 14 min; #+15 =
15 min)
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble
sound.
Each partition turns off its
own trouble sound. No automatic
timeout.
2 = Same as “1”, plus programmed
output device STARTS. If either
partition is armed, external sounder
activates also. External sounder
will be turned off by normal bell
timeout, or by security code plus
OFF from either partition (it does
not have to be the one that was
armed).
[0,0]
1 2
Entry 1: Sets the length of time a phone line fault must remain after
detected before the second digit option is activated.
Entry 2: Selects the desired phone line fault response.
Option 2 may be used even if a relay unit or Powerline carrier device is
not connected to the control.
Programmed Output Device must either be programmed to be
STOPPED in field 80 or STOPPED by entry of [security code] + [#] + 8
+ device number. Partition in 80 should be set to “0,” for STOP.
UL: Field *92 must be enabled for fire alarm installations, UL commercial
burglar alarm installations and UL residential burglar alarm installations.
If the control unit is used on a UL commercial burglar alarm system which
requires 2 methods of remote communication, then the control unit’s DACT
and the other method of signal transmission must monitor each other against
communication failure and line fault. The fault must be received and
annunciated within 200 seconds of its occurrence.