First Alert FA168CPSSIA Home Security System User Manual


 
– 6 –
39
Power Up In Previous State
0 = no, always power up disarmed;
1 = yes, power up in previous state
SIA-Compliant Controls: Feature
always enabled; field does not exist.
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted. Note that if the previous state was armed
Away or Stay, the system ignores sensor changes for 1 minute, which
allows sensors such as PIRs to stabilize.
UL: must be 1
SIA Guidelines: must be 1
DIALER PROGRAMMING (
40 –
42)
40
PABX Access Code or Call
Waiting Disable
Enter up to 6 digits.
To clear entries, press 40.
If call waiting is used, enter call waiting
disable digits “ (#+11) 70” plus “# +
13” (pause).
SIA-Compliant Controls: If call
waiting is used, enter call waiting
disable digits as described above,
and also set Call Waiting Disable
option in field *91.
| | | | |
Call Waiting: If the subscriber’s phone service has “call waiting” (and
is not using PABX), enter “*70” (“# + 11”) plus “# + 13” (pause) as the
PABX entry to disable “call waiting” during control panel calls. If the
subscriber does not have “call waiting” and is not using PABX, make
no entry in this field.
NOTES:
1. The call waiting disable feature cannot be used on a PABX line.
2. Using Call Waiting Disable on a non-call waiting line will prevent
successful communication to the central station.
41
42
Primary Phone No.
Secondary Phone No.
Do not fill unused spaces.
0–9
#+11 for '
'
#+12 for '#'
#+13 for a 2-second pause
| | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. To clear entries, press
41
or
42
respectively
.
Enter the respective phone numbers. If fewer than the maximum digits
entered, exit the field by pressing []. The next data field number is displayed.
43
44
45
46
Partition 1 Primary Acct. No.
Part. 1 Secondary Acct. No.
Partition 2 Primary Acct. No.
Partition 2 Secondary Acct. No.
Enter 4 or 10 digits, as chosen in *48
Report Format. Enter digits 0–9; #+11
for B; #+12 for C; #+13 for D; #+14 for
E; #+15 for F.
| | | / | | | | |
[FFFFFFFFFF]
| | | / | | | | | [FFFFFFFFFF]
| | | / | | | | | [FFFFFFFFFF]
| | | / | | | | | [FFFFFFFFFF]
Enter [] as the fourth digit if a 3-digit account number (for 3+1 dialer
reporting format) is used. Enter 0 as the first digit of a 4-digit account
number for 0000-0999. E.g., For Acct. B234, enter: #+11 + 2 + 3 + 4
To clear entries in a given field, press *43*, *44*, *45*, or *46* based
on the field being programmed
47
Phone System Select
If Cent. Sta. is not
on a WATS line:
0=Pulse Dial; 1=Tone Dial
If Cent. Sta. is on
a WATS line:
2 = Pulse Dial ; 3 = Tone Dial
[1]
Select the type of phone service for the installation.
48
Report F ormat
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD;
2 = 4+2 ADEMCO L/S STAND.
3 = 4+2 RADIONICS STANDARD
5 = 10-digit ADEMCO CONTACT ID®
REPORTING
6 = 4+2 ADEMCO EXPRESS
7 = 4-digit ADEMCO CONTACT ID®
REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXP.;
9 = 3+1, 4+1 RADIONICS EXP
[77]
primary secondary
Select the format for primary/secondary phone numbers
49
Split/Dual Reporting
0 = Standard/backup reporting only (all
to primary)
1-5 = see table at right
[0]
Backup Reporting: All reports are sent only to the primary number
unless unsuccessful after 8 attempts. If unsuccessful, the system will
make up to 8 attempts to send all reports to the secondary number. If
still unsuccessful after the 16 attempts, the system displays the
“COMM. FAILURE” message (FC for fixed-word displays).
Primary Phone No. 2nd Phone No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All