27
ENVISION RESIDENTIAL INSTALLATION MANUAL
PB2
Auxiliary Electric Heat Power
208-230/60/1
Violet
Blu
With optional ' EA' Series
Auxiliary ElectricHeat
Typical schematic shown
2
3
HE1 TS1
HE2 TS2
HE3 TS3
HE4 TS4
P7
L4 L2
L2 NOTE 5
Pink
Yel
Blk
Gray
Pink
Yel
Blk
Gray
Gray
Blk
Yel
Pink
Gray
Pink
Blk
Yel
Pink
Yel
Blk
Gray
Pink
Yel
Blk
Gray
Grn
F2
P9
ER1
ER2
ER3
ER4
L1
L1 L3
NO
NO
NO
NO
Brn
Org
Brn
Or
5
4
Pink
Orange
White
Tan
Blue
Violet
Blue
Yellow
Black
Gray
Red
EA Series PCB
E-Series Logic Board- Physical Layout
1
123
P10
456
P2
1
G G
4
3
2
1
P8
1
2
3
4
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
Switch -Hot Water On/Off
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
F1 and F2 -
FP -
HE -
HP -
LP -
PB1, PB2-
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Freeze protection sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package12 position
DIP package 8position
DIP package 5position
Hot water pump enable switch
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
G
T
132
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4- Aux heat stage relays
HWL -
Hot water limit sensor
123
1
P4
OnOff
SW1
240V - L2
240V - L1
Fused L2
Fused L2
Fused L2
F1
F1
R
R
Microprocessor
E-SeriesLogic Board
CR2- Loop
Pump
N.O.
240V - L2
240V - L1
C
C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
P5
Fused L2
Fused L1
CR1- DHW
Pump
N.O.
CC
CC-GND
CCLO
CCHI
123
P3
2
3
4
5
6
7
8
9
10
11
12
1
OnOff
SW2
2
3
4
5
6
7
8
1
OnOff
SW3
2
3
4
5
P1
12345678
2
345
P2
671
RCY1Y2 GOWL
Shut
Down
ACC
NO
ACC
NC
ACC
COM
CC
SL1
IN
SL1
Out
SL2
IN
SL2
Out
L1 L2
Single Disconnect Power
208-230/60/1
Aux Elect Power
208-230/60/1
L1 L2 L1 L2
Unit Power
208-230/60/1
CSA installed units only
Local codes may require a single
source of power supply
Breaker box
furnished by
installer
Circuit Breakers
N.O.
CR4-
Com
N.O.
CR3-
Com
N.C.
SC -
Start Contactor
Start Relay
SR -
CS - Compressor Solenoid
ECM2
Fan Motor
Grn
15 10163
On/Off
PWM
RPM
C2
RPM grnd
P12
P112 3 4 51
8
CA -
Comfort Alert
NOTES
97P774-02 6/29/06
1. Switch Blue and Red wires for208V operation.
2. Connection of remote unitthat does not havea loop pump for slave operation.
3. 24V Accessory relay (see SW2 -3 for description of operation).
4. The blk/wh and gray/wh wires are removed when Aux Heat is installed.
5. Buss lugsL1 and L2can be removed and dualpower wire sets connected directly to box lugs L1, L2,and L3, L4.
6. DHW pump only in modelswith hot water generation option.
7. Air Flow Configuration Example: SW1 configured for dip 1 as low, dip 3 as medium, and dip 5 as high speed ECM2 fan.
8. SW3-4 should be in theOFF positionwhen using ECM motor and 17P501A01 electric heat board and should be ON when
usingECM2with17P514A01 electricheatboard.
9. SW2-8 must be in the OFF position for pulsed “L” lockout signal andinthe ON position for constant “L” lockout signal.
10. Whenoptionalelectronicair-filterisinstalled,powerfortheelectronicair-filteris providedby P2-2and24VAC.
11. Comfort Alert fault output to Premier Control Board.
12. This switch allows the unit to down stage with the t-stat when off and finish with second stage when on. Finish on second
stage reduces stage changing in recip dual capacity compressors and should be ON for unzoned Dual Cap E Series or
Premier 2 Speed.
Y2
Y
L
R
C
DC
Sol
Data
Port
Comfort Alert Physical Layout
POWER
ALERT
TRIP