Enviro C-11253 Indoor Fireplace User Manual


 
13
Sonnets are to be installed, conrm that the remote control signal codes are
different for each unit.To change the code, complete the following:
1. Change DIP switch position (shown at the top of Figure 13).
2. Press and hold the receiver’s reset button (see Figure 14) until you hear
two (2) acoustic signals. After the second longer acoustic signal, release
Maintenance And Service
CHANGING REMOTE HANDSET CODE & RESETTING RECEIVER:
A code is preset for the remote handset and receiver, but can be changed if required. If one or more
Figure 13: DIP Switch in
Remote Handset Battery
Compartment.
Figure 14: Receiver with Reset Button.
Reset
the reset button and within the
subsequent 20 seconds, press the
(down arrow) on the remote handset
until you hear an additional long
acoustic signal conrming the new
code is set.
Methods for Resetting the Receiver:
Method 1 - From Outside the Cabinet.
The access hole for the reset button is located on the left side of the unit 8
7
/16” (214mm) back from the
front edge of the cabinet. Place a small screwdiver through the hole in the cabinet side (refer to Figure
15) and depress the reset button.
Method 2 - From Inside the Firebox.
Follow steps 1-4 in R
EMOVING VALVE COVER - MAINTENANCE AND SERVICE. Bend a paper clip to reach the
reset button on the left side of the receiver (refer to Figure 16). Depress the reset button using the paper
clip.
Figure 15: Resetting Receiver from Outside. Figure 16: Resetting Receiver from Inside.