Crown Boiler 32 Boiler User Manual


 
10
Table 2: Minimum Room Volumes Based On Sixteen Times Boiler Volume By Model Size
8
Boiler
Model
Over All
Length
Jacket
Over All
Depth
Jacket
Over All
Height
Floor To
Top Of
Jacket
Boiler
Volume
(Ft3)
Minimum
Room
Volume
(Ft3)
32-475 36 3/4 32 1/4 46 5/8 32.0 511.7
32-570 42 1/4 32 1/4 46 5/8 36.7 587.4
32-665 47 5/8 32 1/4 46 5/8 41.4 663.1
32-760 53 1/8 32 1/4 46 5/8 46.2 738.8
32-855 58 1/2 32 1/4 46 5/8 50.9 814.5
32-950 64 32 1/4 46 5/8 55.6 890.2
32-1045 69 3/8 32 1/4 46 5/8 60.4 965.9
32-1140 74 7/8 32 1/4 46 5/8 65.1 1041.6
32-1235 80 1/4 32 1/4 46 5/8 69.8 1117.3
32-1330 85 3/4 32 1/4 46 5/8 74.6 1193.0
32-1425 91 1/8 32 1/4 46 5/8 79.3 1268.7
32-1520 96 5/8 32 1/4 46 5/8 84.0 1344.4
32-1615 102 32 1/4 46 5/8 88.8 1420.1
32-1710 107 1/2 32 1/4 46 5/8 93.5 1495.8
32-1805 112 7/8 32 1/4 46 5/8 98.2 1571.5
32-1900 118 3/8 32 1/4 46 5/8 103.0 1647.2
32-1995 123 3/4 32 1/4 46 5/8 107.7 1722.9
32-2090 129 1/4 32 1/4 46 5/8 112.4 1798.6
32-2185 134 5/8 32 1/4 46 5/8 117.1 1874.3
32-2280 140 1/8 32 1/4 46 5/8 121.9 1950.1
32-2375 145 1/2 32 1/4 46 5/8 126.6 2025.8
32-2470 151 32 1/4 46 5/8 131.3 2101.5
32-2565 156 3/8 32 1/4 46 5/8 136.1 2177.2
32-2660 161 7/8 32 1/4 46 5/8 140.8 2252.9
32-2755 167 1/4 32 1/4 46 5/8 145.5 2328.6
32-2850 172 3/4 32 1/4 46 5/8 150.3 2404.3
Figure 3: Clearances To Combustible Construction