Vermont Casting 2465 Indoor Fireplace User Manual


 
6
Dutchwest Direct Vent / Natural Vent Gas Heater
30001935
Parallel Installation:
Minimum Clearance and Flue Centerline,
Direct Vent and Natural Vent
ST128b
Stardance
flue centerline
9/28/00 djt
C
L
C
L
B
D
C
A
ST128c
Stove Clearances A: 4” (102 mm)
B: 4” (102 mm)
Pipe Centerlines C: 15¹⁄₂” (395 mm)
D: 9” (229 mm)
Fig. 3 Parallel installation, minimum back and side clear-
ances and flue centerlines.
Corner Installation:
Minimum Clearance and Flue Centerline
Direct Vent and Natural Vent
ST129c
Dutchwest
corner specs
5/15/03 djt
A
A
B
B
ST129c
Stove Clearance A: 4” (102 mm)
Pipe Centerline B: 14¹⁄₂” (370 mm)
Fig. 4 Corner installation, minimum corner clearances and
flue centerline.
Wall Centerline from Floor
ST131c
Dutchwest
wall thimble
5/15/03 djt
A
A
Effective Minimum
Wall Thimble 57
¹⁄₂” (1461 mm) (CFM Pipe)
Centerline 53
¹⁄₂” (1359 mm) (Simpson DuraVent Pipe)
ST131c
Fig. 5 Minimum wall thimble centerline.
Wall and Ceiling Clearances
A
C
D
ST101c
Dutchwest
Direct Vent
Min. Clrnc
5/15/03 djt
B
A: Rear Wall 4” (102 mm)
B: Min. Clearance 45¹⁄₂” (1156 mm)*
C: Min. Alcove Height 73¹⁄₂” (1867 mm)*
D: Max. Alcove Depth 48” (1220 mm)
Sidewall Clearance 4” (102 mm)
* needed for installing DuraVent Minimum Vent Kit #2792 or CFM Corpora-
tion Minimum Vent Kit #7TFSDVSK.
ST101c
Fig. 6 Dimensions and clearances to ceiling or alcove.
Hearth Requirements
The Dutchwest Heater must be installed on rigid floor
-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.