21. Replace burner. Slide the burner in at an angle
with left side lower than the right side. Slide the left
side onto the injectors, making sure the burner leg
remains at a 90° angle to the base. Lower the right
hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.
NOTE: It is very critical to keep the left burner leg,
which holds the injectors, at a 90° angle to the base.
(Fig. 57) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.
22.Place conversion label on valve.
23.Reinstall the right and left log bracket assembly.
24.Reinstall the rear log bracket.
25.Replace logs.
26.Replace glass and stove front.
Conversion is complete.
ST353
air shutter adjust
burner replace
3/20/00 djt
90°
Left Burner Leg
Injector Shoulder
ST353
Fig. 57 Be sure to maintain 90° angle at left burner leg.
Conversion to Natural Gas Input (BTU/h)
Kit # Front Part # Rear Part # Minimum Maximum
000-5021 #54 / .055” 30000514 #44 / .086” 30000334 19,000 28,000
Conversion to LP Input (BTU/h)
Kit # Front Part # Rear Part # Minimum Maximum
000-5022 #69 / .029” 30000513 #54 / .055” 30000514 20,000 28,000
Table 2. Injector Orifice Size Matrix