Table 2 — Physical Data 581C (cont)
UNIT SIZE 581C 024 036 048 060
FURNACE SECTION
Rollout Switch Cutout Temp (F)† 195 195 195 195
Burner Orifice Diameter (in. ...drill size)**
Natural Gas —Std 071/072 .113...33 .113...33 .113...33 .113...33
114/115 .113...33 .113...33 .113...33 .113...33
149/150 .129...30 .129...30 .129...30
060N .102...38 .102...38 .102...38
090N .102...38 .102...38 .102...38
120N .116...32 .116...32
Propane —Alt†† 071/072 .089...43 .089...43 .089...43 .089...43
114115 .089...43 .089...43 .089...43 .089...43
149/150 .102...38 .102...38 .104...39
060N .082...45 .082...45 .082...45
090N .082...45 .082...45 .082...45
120N .094...42 .094...42
Thermostat Heat Anticipator Setting (amps)
208/230/460 v
FirstStage .14 .14 .14 .14
Second Stage .14 .14 .14 .14
GasInput(Btuh)
First Stage/Second Stage (3---phase units) 072 50,000/72,000 50,000/ 72,000 50,000/ 72,000 50,000/ 72,000
115 82,000/115,000 82,000/115,000 82,000/115,000 82,000/115,000
150 120,000/150,000 120,000/150,000 120,000/150,000
071II —/72,000 —/72,000 —/72,000
114II —/115,000 —/115,000 —/115,000
149II —/150,000 —/150,000
060N*** —/ 60,000 —/60,000 —/60,000
090N*** —/ 90,000 —/90,000 —/90,000
120N*** —/120,000 —/120,000
Efficiency (Steady State) (%) 072 82 82 82 82
115 80 81 81 81
150 80 80 80
071 82 82 82
114 80 81 81
149 80 80
060N 80 80 80
090N 80 80 80
120N 80 80
TemperatureRiseRange 072 15---45 15---45 15---45 15 ---45
115 55---85 35---65 35---65 35 ---65
150 50---80 50---80 50---80
071 15---45 15---45 15---45
114 55---85 35---65 35---65
149 50---80 50---80
060N 20---50 20---50 20---50
090N 30---60 30---60 30---60
120N 40---70 40---70
ManifoldPressure(in.wg)
Natural Gas —Std 3.5 3.5 3.5 3.5
Propane —Alt†† 3.5 3.5 3.5 3.5
Maximum Static Pressure (in. wg) 1.0 1.0 1.0 1.0
Field Gas Connection Size (in.) 1/2 1/2 1/2 1/2
HIGH-PRESSURESWITCH (psig)
Standard Compressor Internal Relief
450 50
Cutout
428
Reset (Auto.)
320
LOSS-OF-CHARGESWITCH/LOW-PRESSURE
(Liquid Line) (psig)
Cutout
7 3
Reset (Auto.)
22 5
FREEZEPROTECTIONTHERMOSTAT
Opens (F)
30 5
Closes (F)
45 5
OUTDOOR-AIR INLETSCREENS
Cleanable. Screen quantity and size varieswith option selected.
RETURN-AIR FILTERS
Throwaway
Quantity...Size(in.)
2...16 x 25 x2 4...16x 16 x 2
LEGEND
Bhp Brake Horsepower
**60,000 and 72,000Btuh heat input unitshave 2 burners.90,000 and 120,000 Btuh
heat i nput units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh
Heat input unitshave 3burners.
††A propane kitis available asan accessory.Kitmaybe usedat elevationsas highas
2000 ft. If a propane kit is used with Low NOx units, the Low NOx baffle must be
removed and theunitswill no longer beclassified asLow NOxunits.
ll Three-phase standard models have heating inputs as shown. Single-phase stan-
dard models have one-stage heating with heating inputvalues.
***Californiacompliantthree-phasemodels.
†††California SCAQMD compliantlow NO
x
modelshave combustionproducts that are
controlledto40nanogramsperjouleorless.
581B,C