Brother BAS-311E Sewing Machine User Manual


 
89
BAS-311E.311EL.326E.326EL
Chapter 6 Power supply and electrical parts adjustment
[Set value]
0: Sensor home position, 1: Center of sewing area, 2: Upper
left of sewing area, 3: Lower left of sewing area, 4: Upper
right of sewing area, 5: Lower right of sewing area, 6:
Sewing start point, 7: Sewing end point, 8: Upper left of
mask, 9: Lower left of mask, 10: Upper right of mask, 11:
Lower right of mask
[Procedure]
1. Select memory switch 39.
2. Change X and Y scales.
3. Step on start switch to return to home position, and
sewing data can be created with specified scales.
[Mask]
Upper left
of mask
Lower left
of mask
memo-37 0 - 3
----
3
Gear ratio is automatically corrected when 2DD data is read.
0: Follows the model specified in DIP switch C.
1: Reads 2DD data as 311A data.
2: Reads 2DD data as 326A data.
3: Reads 2DD data as 341A/342A data.
[This function is available when panel PROM indication is
PL-C or later.]
Changes the possible sewing speed for a given stitch length.
1 (Fast) 7 (Slow)
1 (2,700/3 mm), 2 (2,600/3 mm), 3(2,500/3 mm),
4 (2,300/3 mm), 5 (2,000/3 mm), 6 (1,800/3 mm),
7 (1,200/3 mm)
Settings 1 and 2 are outside the warranty specification at the
time of shipment from the factory.)
memo-30
memo-31
memo-32
memo-33
memo-34
memo-35
memo-36
memo-38
Possible setting
range
1 - 999
1 - 4
1 - 7
1 - 10
1 - 5
10 - 60
1 - 3
1 - 20
Units
x
10ms
----
----
x 7.5°
----
Xms
----
X0.1S
Initial
value
10
1
3
5
0
40
1
1
Explanation
Time until feed mechanism starts moving after
work clamp has lifted.
Changes the feed speed. 1 (Fast) 4 (Slow)
Changes the feed timing
1 (Fast) 5 (standard) 10 (Slow)
Number of stitches sewn at 400 spm (10W speed) at sewing
start
Solenoid ON time changes when work clamp is being
lowered (solenoid specifications only)
10 60
(Quiet) (High work clamp capacity)
ç
Solenoid ON time to raise presser foot is changed.
(Standard) 1 3 (Upper limit)
1 (10 ms) 2 (20 ms) 3 (30 ms)
Delay time from the point when the cassette is
clamped to the start of sewing when DIP switch A7 is
ON during automatic sewing
SW No.
memo-39 0 - 11 ---- 0
Mask is a rectangular frame
to cover the rounded edges
of sewing data.
In the left figure, an oval is
sewing data, and the
rectangle indicated with a
broken line is the mask.
¡
¡
Î
Turn the dial while pressing the STEP BACK switch to change the values.
Turn the dial while pressing the STEP BACK switch to change the values.
Note:Ç · Î · Ï indicates that these functions are available for software versions MN-C · MND · MN-F or later.