Chapter 6 Power supply and electrical parts adjustment
memo-10
memo-11
memo-12
memo-13
memo-14
memo-15
memo-16
memo-17
memo-18
memo-19
memo-1A
memo-1b
memo-1c
memo-1d
memo-1E
memo-1F
When ON
Milling device can be used (available as an option).
Bobbin thread counter and production counter operate every time thread is trimmed.
Work clamp is lowered by pressing work clamp first stage switch twice, without using work clamp
second stage switch. When DIP switch A-2 is set to ON, right work clamp and left one are lowered
in this order; when OFF, left work clamp and right one are lowered in this order. They are raised
simultaneously.
When the work clamp is lowered, pressing the start switch causes locking; if the switch is released
before locking, the work clamp is raised. When DIP switch A-2 is set to ON, the right work clamp
and the left one are lowered in this order; when OFF, the right work clamp and the left one are
lowered in this order. They are raised in the reverse order.
Needle up error is detected.
ON when machine is equipped with signal tower indicator.
(This indicator is available by special order.)
ON when machine is equipped with thread nipper. (Thread nipper is available by special order.)
After presser foot rises, thread nipper will operate.
ON when machine is equipped with reset switch. (Reset switch is available by special order.)
When the start switch is pressed, the right work clamp and the left one are lowered in this order,
and sewing starts. When the work clamp first stage switch is pressed, the left work clamp and
right one are lowered in this order (when DIP switch A-2 is set to ON). When DIP switch A-2 is set
to OFF, the order is reversed.
Produces three work clamp signal outputs (right and left work clamps, and presser foot) so that a
two-position air valve can be used. (Two-position air valve is available by special order.)
When using a triple pedal (DIP switch B-7 is also ON), the right is used exclusively to detect the
home position. If DIP switch A-7 is OFF, the left pedal causes left and right work clamps to be
raised and lowered simultaneously. If ON, the left pedal causes the left work clamp to be raised
and lowered, and the starting pedal causes the right work clamp to be lowered.
B430E single foot pedal can be used. DIP switch A-7 should be ON.
Bobbin thread counter is decremented at the start of sewing.
An air pressure drop detection switch is used. (This detection switch is available by special order.)
Split number is changed automatically.
Program number is changed automatically.
SW No.
Memory Switches (10 – 1F)