Brother BAS-311E Sewing Machine User Manual


 
84
BAS-311E.311EL.326E.326EL
Chapter 6 Power supply and electrical parts adjustment
DIP switches inside the control box
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from
the wall outlet before opening the face plate of the control box. Touching areas where high volt-
ages are present can result in severe injury.
DANGER
DIP switch C
c-4
c-5
c-6
c-7
c-8
When ON
Controlled sewing area becomes 1200 mm × 400 mm
5 For pneumatic type, set to ON when the connection has been changed so that the work clamp remains
raised when the power is turned off.
Stepping work clamp operated by air pressure is used (when solenoid type is standard).
----------------
----------------
SW No.
ON
ON
ON
ON
c-2
ON
ON
ON
ON
c-3
ON
ON
ON
ON
Model
BAS311E
BAS326EL
BAS311EL
c-1
Area (X, Y)
130 60
220 100
220 60
Main PCB