Bosch Appliances MIC612 Home Security System User Manual


 
70 en | MIC612 Thermal Camera
F.01U.249.416 | 2.0 | 2012.09 Installation Manual Bosch Security Systems, Inc.
On/Off 81 Alarm Output 1
Open Collector
On–Activates output.
Off–Deactivates output.
On/Off 82 Alarm Output 2
Open Collector
On–Activates output.
Off–Deactivates output.
On/Off 83 Alarm Output 3
Open Collector
On–Activates output.
Off–Deactivates output.
On/Off 84 Alarm Output 4
Relay
On–Activates output.
Off–Deactivates output
On/Off 88 Proportional PTZ On–Activates Proportional PTZ.
Off–Deactivates Proportional PTZ.
On/Off 90 Command Lock/Unlock On–Turns on the lock.
Off–Turns off the lock.
On/Off 97 Video channel (toggle) On - Switches view to thermal camera.
Off - Switches view to optical camera.
On 99 Factory P/T Home Position Recalibrates home position; can be used as an
Alarm Output.
On/Off 100 Record A Activates/Deactivates recording A.
On/Off 101 Record B Activates/Deactivates recording B.
102 Wiper alarm Turns the wiper alarm on/off manually.
103 Wiper wipe Activates the wiper in Intermittent mode (the
wiper wipes twice, then turns off after 15
seconds).
104 Wiper wipe Activates (On shot) to wipe five times, then turn
off.
105 Washer/Wiper Activates the washer/wiper.
On 454 White Hot Activates thermal display mode White Hot.
Off 454 Black Hot Activates thermal display mode Black Hot.
On 455 Ice Fire Activates thermal display mode Ice Fire.
Off 455 Globow Activates thermal display mode Globow.
On 456 Ironbow 1 Activates thermal display mode Ironbow 1.
Off 456 Ironbow 2 Activates thermal display mode Ironbow 2.
On 457 Rainbow Activates thermal display mode Rainbow.
Off 457 Fusion Activates thermal display mode Fusion.
On 458 Sepia Activates thermal display mode Sepia.
Off 458 Rain Activates thermal display mode Rain.
On 459 Color 1 Activates thermal display mode Color 1.
Off 459 Color 2 Activates thermal display mode Color 2.
On 460 Red Hot Activates thermal display mode Red Hot.
Off 460 Green Hot Activates thermal display mode Green Hot.
On 463 SPOT meter display Activates the SPOT meter.
Off 463 SPOT meter display Deactivates the SPOT meter.
On 997 FastAddress, display Display the current FastAddress of the camera.
On 998 FastAddress, all units Displays the current FastAddress of the camera
and programs all units.
On 999 FastAddress, unaddressed cameras Displays and programs unaddressed MIC612
units.
Set “1-99” Pre-position Programming Set ##–Programs a preset view.
Shot “1-99” Pre-position Recall Shot ##–Recall programmed preset.
Set/Shot 100 Pre-position Store/Clear Enters/ Exits pre-position menu.
Set/Shot 101 Autopan Left Limit Set–Programs left limit.
Shot–Shows limit.
Locked Function
Key
Command
No.
Command Description