ON-998-ENTER: Displays and programs all cameras with or without an address in the
system.
ON-997-ENTER: Displays the current address status of all cameras in the system
simultaneously.
To set an address for a camera without an address:
1. Select the camera number that you want to FastAddress. The system displays the
camera number on the keyboard and the image on the corresponding monitor.
2. Press #-ENTER (where # is the camera number without an address).
3. Press ON-999-ENTER to invoke an on-screen display of cameras on the system without
an address.
4. Follow the on-screen instructions. You receive an on-screen confirmation when the
FastAddress is complete.
To change or clear an address for a camera with an address:
1. Select the camera number that you want to FastAddress. The system displays the
camera number on the keyboard and the image on the corresponding monitor.
2. Press #-ENTER (where # is the camera number with an address).
3. Press ON-998-ENTER to invoke an on-screen display of all cameras on the system, with or
without an address.
4. Follow the on screen instructions. You receive an on-screen confirmation when the
FastAddress is complete.
The table below identifies the setting of the thermal camera when you change the address of
the optical camera.
You can change the address of the thermal camera via CTFID; there is no Aux code for this.
5.4.3 FastAddress, Pelco Protocols
This section provides instructions to set a FastAddress with a Pelco keyboard or controller.
The optical camera of the MIC612 with an address set to 0 responds to commands set to
any address.
Pelco-P protocol must use addresses 1 to 32.
Pelco-D protocol must use addresses 1 to 254.
To set FastAddress with a Pelco Keyboard:
1. Press and hold 95-PRESET for two seconds to open the Pelco Setup menu.
2. Move the joystick to select the Command Lock menu.
3. Press the FOCUS or the IRIS button to turn Command Lock to OFF.
4. Move to the FastAddress menu and press the FOCUS button or the IRIS button to open
the menu.
Default Address, Optical New Address, Optical Camera Address, Thermal Camera
0 A number other than 0 The number of the optical
camera + 1
A number other than 0 0 or another number -No change of address.-
NOTICE!
A previously-configured MIC612 with an address above 32 (Pelco-P upper limit) or 254 (Pelco-
D upper limit) can be used without readdressing the unit. However, no two (2) addresses can
be the same. For example:
Pelco-P addresses above 32 are repeated in multiples of 32 (1, 33, 65, 97 are the same).
Pelco-D addresses above 254 are repeated in multiples of 254 (1, 255, 509, 763 are the
same).