Bosch Appliances MIC612 Home Security System User Manual


 
MIC612 Thermal Camera On-Screen Display (OSD) Menus (Bosch Protocol) | en 45
Bosch Security Systems, Inc. Installation Manual F.01U.249.416 | 2.0 | 2012.09
6.6 Communication Setup Menu
The Communication Setup Menu contains baud rate and Bilinx control settings.
AutoBaud
Turns on AutoBaud detection, which detects and adjusts the camera protocol and baud rate
to match that of the controller. Options: ON (default setting), OFF. ON automatically accepts
baud rates from 2400 to 57600.
Note: If stepping from 2400 to 57600 baud, you must first set the Baud Rate to 19200 for
AutoBaud to detect the higher baud rate.
Baud Rate
Manually sets the baud rate when AutoBaud is set to OFF. Options are 2400, 4800, 9600
(default setting), 19200, 38400, and 57600.
Bilinx
Activates Bilinx control communication. (Only available when not connected to a Bilinx data
interface unit.) Options: ON (default setting), OFF.
Communication Setup
Exit...
* AutoBaud: ON
* Baud Rate: 9600
Bilinx
Restore Defaults
* = Factory Setting
Focus / Iris: Select