Bosch Appliances MIC612 Home Security System User Manual


 
48 en | On-Screen Display (OSD) Menus (Bosch Protocol) MIC612 Thermal Camera
F.01U.249.416 | 2.0 | 2012.09 Installation Manual Bosch Security Systems, Inc.
Rule Setup Submenu
Rule Setup Submenu Choices:
Rule Setup
Displays the status of rules and lets you add new rules or modify an existing rule.
Rule 1-12
Displays the status of a rule on the right side of the menu. Rule status options:
Selecting a Rule number provides access to its configuration menu. The Rule # Menu allows
you to configure a rule from previously-defined alarm inputs and outputs. Once an alarm is
configured with valid inputs and outputs, it can be turned on or off (enabled or disabled)
through its configuration menu.
Rule # Choices:
Enabled
Turns the rule on or off after its inputs and outputs have been defined.
YES to enable or NO to disable (default setting)
NOTICE!
You can program a total of twelve rules. You must define the inputs and outputs before you
program a rule. See Section 6.7 Alarm Setup, page 46, to configure alarm inputs and outputs.
Rule Setup... Rule 1
Exit... Exit...
1. Rule 1 Enabled Enabled YES
2. Rule 2 Disabled Input:
3. Rule 3 Invalid NONE
4. Rule 4 Empty NONE
5. Rule 5 Empty NONE
6. Rule 6 Empty
7. Rule 7 Empty Output:
8. Rule 8 Empty OSD
9. Rule 9 Empty Shot 2
10. Rule 10 Empty Alarm Relay 2 sec
11. Rule 11 Empty NONE
12. Rule 12 Empty
Right / Left: Select Period Time
Focus / Iris: Select Focus / Iris: Select Type
Option Description
Enabled The rule inputs and outputs are properly defined and the rule is turned on.
Disabled The rule inputs and outputs are defined but the rule is turned off.
Invalid The rule has a missing or invalid input or output.
Empty (Default setting) The rule has no inputs or outputs defined.