Toshiba RAV-SP180KRT-UL Air Conditioner User Manual


 
High-Wall Type
Owner’s Manual
–31–
Toshiba
10. POWER SAVING MODE
The power saving mode saves energy by limiting the maximum current which will effect heating or cooling
capacity that the unit can generate.
Push button during operation.
The air conditioner enters power saving mode.
appears on the display.
Power saving mode will stay in effect until it is cancelled.
To cancel the power saving mode, push button again.
disappears.
NOTE
Power saving mode consumes less energy, but may not heat/cool the room as much as normal mode.
(The maximum current is limited to approximately 75% (factory default) of the normal mode.)
This Value can be adjusted between 50% to 99%.
Even when operation start/stop, operation mode change, or power reset is performed during the power
saving mode, the power saving mode is retained until the next operation.
Change power saving mode setting
1 Push button for at least four
seconds when the air conditioner is not
working.
and numbers flash.
2 Push (left side of button) to select
an indoor unit to be set.
Each time you push the button, unit numbers
change as follows:
The fan of the selected unit runs and the louvers start
swinging.
3 Push TIME buttons to adjust the
power-save setting.
Each push of the button changes the power level
by 1% within the range from 100% to 50%.
* The factory default is 75%.
4 Push button.
5 Push button to complete the setting
1
3
4
5
2
UNIT No.
1-1
UNIT No.
1-2
UNIT No.
1-3
UNIT No.
1-4
Setting of power level in power
saving mode
31-EN
+001111052101_00Ta.book Page 31 Friday, November 20, 2009 1:13 PM