State Industries 740A Water Heater User Manual


 
22
FOR YOUR SAFETY READ BEFORE LIGHTING
1. Remove thermostat control cover.
2. Set thermostat to lowest setting.
3. Turn burner switch to “OFF”.
WARNING: 
explosion may result causing property damage, personal injury or
loss of life.
A. This appliance is equipped with an ignition device which
automatically lights the burner.
Do NOT try to light burner by hand.
B. BEFORE LIGHTING: Smell all around the appliance area
for gas. Be sure to smell next to the oor because some
gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don’t try to repair it, call a qualied service technician. Force
or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
E. Do not operate appliance unless unit is lled with water
and inlet lines are fully open.
1.  Read the safety information above on this
label.
2. Remove appliance thermostat cover. Rotate thermostat
dial counterclockwise
to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped an ignition device which
automatically lights the burner. Do NOT try to light the
burner by hand.
5. Refer to diagrams above. Turn top knob of gas control
clockwise to “OFF” position (Figure A).
6. Wait ve (5) minutes to clear out any gas. If you then smell
gas,
STOP! Follow “B” in the safety information above
on this label. If you don’t smell gas, go to next
step.
7. Turn top knob of gas control counterclockwise
to
“ON” (Figure B).
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
8. Turn on all electric power to the appliance.
9. Set thermostat to desired setting.
10. Turn switch to “ON” position.
11. Heater will automatically begin operation. Blower motor
will run approximately 40 seconds, then pilot gas valve
will open. Upon conrming the pilot ame the main gas
valve will open and the heater will operate in heating
mode. Reference “Sequence of Operation” section of
manual for details.
12. Heater is equipped with an ignition module which locks out
after one (1) unsuccessful ignition attempt. Blower motor
will continue to run. If lockout occurs, turn burner switch to
“OFF” position for at least one minute, then turn the switch
back to “ON”. Heater will automatically begin operation.
13. Replace thermostat control cover.
14. If the appliance will not operate, follow the instructions
“TO TURN OFF GAS APPLIANCE” and call your service
technician or gas supplier.
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.
4. Turn off all electric power to the appliance if service is
to be performed.
5. Turn top knob of gas control to the “OFF” position. Refer
to Step 5 of ‘OPERATING INSTRUCTION” above.
6. Replace thermostat control cover.
FIGURE “A”
“OFF POSITION”
FIGURE “B”
“ON POSITION”