Sanyo CH4272R H/P Air Conditioner User Manual


 
80
RC
(WL)
7-18. Wiring System Diagram for Multiple Remote Controllers
When installing multiple remote controllers
This multiple system is used for operating the unit(s) at
different positions. (A maximum of 2 signal receiving
units can be installed.)
Setting method
To execute this control, make the setting according
to the following procedure.
(1) Of the two installed signal receiving units, make
one the main
signal receiving unit (factory-
shipped state).
(2) On the other signal receiving unit, change the
address connector on the PCB from main to sub
position.
In this state, it functions as a sub-signal receiving
unit.
Basic wiring diagram
Carry out the wiring correctly
(incorrect wiring will damage
the equipment).
To operate 1 indoor unit with 2 signal receiving units
set at different locations.
CAUTION
Connection wiring
Signal receiving unit
1
2
Indoor unit
Earth
(sub)(main)
1
2
(Option)
1
2
Remote control
cable terminal
board