Sanyo CH4272R H/P Air Conditioner User Manual


 
43
K
3-16. Wiring Instructions for Inter-Unit Connections
(1) Insert the inter-unit wiring (according to local
electrical codes) into the through-the-wall PVC
pipe. Run the wiring toward the indoor side allowing
approx. 10 inches to extend from the wall face.
(Fig. 3-57)
(2) Route the inter-unit wiring from the back of the
indoor unit and pull it toward the front for
connection. (Figs. 3-58a and 3-58b)
(3) Connect the inter-unit wiring to the corresponding
terminals on the terminal plate (Figs. 3-58a and
3-58b) while referring to the wiring diagram.
(4) Be sure to secure the wiring with the provided
clamp.
How to remove the cover plate
To access the terminal plate inside the indoor unit,
follow these steps.
(1) Using a Phillips screwdriver, remove the screw on
the cover plate. (Figs. 3-58a and 3-58b)
(2) Remove the cover plate.
KH(S)2672R
Rear
panel
Wiring
Wall
10 in.
Plastic
cover
Fig. 3-57
Terminal
plate
Cover plate
Fig. 3-58a
Lock nut
Top of conduit
connector
Inter-unit
control line
wiring
Earth
plate
Fig. 3-58b
07-115 SSHP_II 5/7/07 4:00 PM Page 43