Rinnai 37AHB Furnace User Manual


 
Rinnai Corporation Hydronic Furnace (37AHB) Manual 49
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
1934 1889 1857 1818 1784 1750 1715 1680 1568 1491 1377
120 60.7 59.3 58.3 57.1 56.0 55.0 53.9 52.8 49.2 46.8 43.2
130 72.1 70.4 69.2 67.8 66.5 65.3 64.0 62.6 58.5 55.6 51.3
140 83.7 81.8 80.4 78.7 77.3 75.8 74.3 72.7 67.9 64.6 59.6
150 95.2 93.0 91.4 89.5 87.8 86.2 84.4 82.7 77.2 73.4 67.8
160 106.9 104.4 102.6 100.5 98.6 96.7 94.8 92.8 86.7 82.4 76.1
1777 1732 1694 1650 1630 1592 1553 1517 1464 1441 1361
120 59.1 57.6 56.4 54.9 54.2 53.0 51.7 50.5 48.7 47.9 45.3
130 69.5 67.8 66.3 64.5 63.8 62.3 60.8 59.3 57.3 56.4 53.2
140 81.1 79.1 77.4 75.3 74.4 72.7 70.9 69.3 66.9 65.8 62.1
150 92.5 90.2 88.2 85.9 84.9 82.9 80.9 79.0 76.2 75.0 70.9
160 103.5 100.9 98.7 96.1 95.0 92.8 90.5 88.4 85.3 84.0 79.3
1573 1530 1490 1448 1417 1372 1327 1293 1253 1221 1175
120 55.8 54.3 52.9 51.4 50.3 48.7 47.1 45.9 44.4 43.3 41.7
130 67.4 65.5 63.8 62.0 60.7 58.8 56.8 55.4 53.7 52.3 50.3
140 77.5 75.4 73.4 71.3 69.8 67.6 65.4 63.7 61.7 60.1 57.9
150 87.7 85.3 83.1 80.7 79.0 76.5 74.0 72.1 69.9 68.1 65.5
160 99.1 96.3 93.8 91.2 89.2 86.4 83.6 81.4 78.9 76.9 74.0
1400 1351 1317 1275 1225 1183 1134 1095 1053 1011 951
120 54.5 52.6 51.3 49.7 47.7 46.1 44.2 42.6 41.0 39.4 37.0
130 63.2 61.0 59.5 57.6 55.3 53.4 51.2 49.4 47.6 45.7 42.9
140 74.1 71.5 69.7 67.5 64.8 62.6 60.0 57.9 55.7 53.5 50.3
150 85.0 82.0 79.9 77.4 74.4 71.8 68.8 66.5 63.9 61.4 57.7
160 94.4 91.1 88.8 86.0 82.6 79.8 76.5 73.8 71.0 68.2 64.1
Optimal Legs @
50 CFM/Leg
Maximum legs @
40 CFM/Leg
Minimum Legs @
60 CFM/Leg
Optimal Legs @
50 CFM/Leg
Maximum legs @
40 CFM/Leg
Minimum Legs @
60 CFM/Leg
Optimal Legs @
50 CFM/Leg
Maximum legs @
40 CFM/Leg
Minimum Legs @
60 CFM/Leg
Optimal Legs @
50 CFM/Leg
Maximum legs @
40 CFM/Leg
Number of 3" Diameter Branch Legs applicable to High
Velocity Systems Only. Used only if methods other
than Table 3 is used to determine duct sizes.
40
TABLE 5.17: AIR DELIVERY AND PERFORMANCE DATA (BOTTOM OR SIDE RETURN w/ FACTORY SUPPLIED FILTER)
UNIT
SIZE
AHB90 + R94LSi(e)
AIRFLOW (CFM)
TAP 4
(L)
3.0
NET
HEATING
CAPACITY
(MBH)
27 32 40
AHB90 + R94LSi(e)
AIRFLOW (CFM)
TAP 3
(ML)
3.5
NET
HEATING
CAPACITY
(MBH)
27 32 40
Minimum Legs @
60 CFM/Leg
AHB90 + R94LSi(e)
AIRFLOW (CFM)
TAP 2
(MH)
4.0
NET
HEATING
CAPACITY
(MBH)
27 32 40
37AHB09016KA5 + REU-VB2735FFUD(WD)-US
AHB90 + R94LSi(e)
AIRFLOW (CFM)
TAP 1
(H)
5.0
NET
HEATING
CAPACITY
(MBH)
27 32
ECM
SPEED
TAP
SUPPORTS
COOLING CAP.
RANGE (TONS)
EWT (
O
F)
NOMINAL
HEATING
CAPACITY
External Static Pressure (ESP)
NOTES:
1. EWT - Entering Water Temperature (F).
2. CFM - Airflow in (Cubic Feet per Minute).
3. Legs - 3 inch diameter flexible ducts to diffusers.
4. 1 MBH = 1000 BTU/H.
5. Shaded box represents rating point; refer to wiring diagram for factory set speed taps.
6. Number of 3” diameter legs specified in table above is for rating point only (i.e. at External Static Pressure of 0.5
in. wc. and speed TAP3, TAP1, TAP2 , TAP2 for AHB45, AHB60, AHB75, AHB90 respectively). Final leg count is
to be determined by the installing contractor and is to be based on the following formula:
NUMBER OF LEGS = TOTAL AVAILABLE CFM
(AT THE SPECIFIC ESP)
/ DESIRED CFM per LEG
(40, 50, or 60 CFM)
Example: Given the design point for AHB045 of 0.8 ESP, Low fan speed (Tap5). From table 5.0, available CFM is
569 and the desired CFM per leg is 50 CFM. Therefore, Number of Legs = 569/50 = 11.38 rounded down to 11.
TBD
See Note 6.
TBD
See Note 6.
TBD
See Note 6.
TBD
See Note 6.
TBD
See Note 6.
TBD
See Note 6.
TBD
See Note 6.
TBD
See Note 6.
TBD
See Note 6.
in. W.C.