Quadra-Fire QFP38-LP Indoor Fireplace User Manual


 
Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/0962
Repeat with the other light box.
Figure 15.26 Finished Assembly
Switch the control module to “ON” and/or plug light cord
(white) into module.
Plug brown wires into the back of the ON/OFF switch on
the dashboard, reattach dashboard with the two screws
removed in the rst step.
To Close
To Open
Air Shutter
Adjustment
Remove
Screw
Replace
Screw
Rotate
Lever
1
2
3
4
Position 1 - Horizontal and up to 8 ft (2.45 m) vertical
Position 2 - 8-16 ft (2.45-4.88 m) vertical
Position 3 - 16-30 ft (4.88-9.14 m) vertical
Position 4 - Over 30 ft (9.14 m) vertical
Figure 15.28 Adjust the Vertical Baf e
Figure 15.27 Adjusting the Air Shutter
I. Adjust the Air Shutter
This appliance has two adjustable air shutters (to control
the primary air) which are set at the factory.
A natural gas unit is set in the closed position.
An LP gas unit is set in the open position. See
Figure 15.27.
If it is necessary to adjust the air shutter to obtain
optimal ame appearance, this should be adjusted by
a quali ed installer.
J. Adjust the Vertical Baf e
If the vertical vent run height is more than 8 ft (2.45 m),
it may be necessary to adjust the vertical baf e installed
in the unit to improve the ame appearance. See Fig-
ure 15.28.