Q. Lighting Instructions (IPI)
For normal use, activate/deactivate your replace with the remote control.
The IPI system may be operated with four AA batteries.
• If your replace must be deactivated for serviced or an extended period of time, follow the instructions below.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. DO NOT try to light the pilot by
hand.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO
APPLIANCE
1. Press “ON/OFF” key on the transmitter.
2. Turn OFF all electric power to the appliance if service is to be
performed.
3. Turn gas supply OFF.
Due to high surface temperatures, keep children, clothing and furniture away.
Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property
damage, personal injury or loss of life.
FOR YOUR SAFETY READ BEFORE LIGHTING
4061-309a
C. Use only your hand to turn the gas control knob. Never use
tools. If the lever or knob will not move by hand, don't try to
repair it, call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
This appliance needs fresh air for safe operation
and must be installed so there are provisions for
adequate combustion and ventilation air.
This appliance must be installed in accordance with
local codes, if any; if not, follow ANSI Z223.1 or, in
Canada, current CAN/CGA-B149.
WARNING:
Improper installation,
adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to the
owner's information manual provided with the
appliance. For assistance or additional information
consult a qualified installer, service agency or the
gas supplier.
CAUTION:
Hot while in operation. Do not touch.
Keep children, clothing, furniture, gasoline and other liquids
having flammable vapors away.
WARNING RISK OF FIRE
This appliance is intended to burn a specified gas fuel only. Do
not attempt to use with solid wood fuel or another type of fuel.
Do not attempt to modify or use any other type of gas burner
system.
*Also certified for installation in a bedroom or a
bed-sitting room.
*For U.S. only!
WARNING:
Disconnect the electric power before
servicing. If for any reason the original wire supplied with the
appliance must be replaced, it must be replaced with 105° C or its
equivalent.
This appliance must be properly connected to a
venting system in accordance with the
manufacturer's installation instructions.
NATURAL GAS
1. STOP! Read the safety information above on this label.
2. Turn OFF the gas supply to the appliance.
3. Turn OFF all electric power to the appliance.
4. This appliance is equipped with an ignition device which
automatically lights the pilot. DO NOT try to light the pilot
by hand.
5. Wait five minutes to clear out any gas. If you then smell gas,
STOP! Follow "B" in the safety information above on this label. If you
don't smell gas, go to the next step.
6. To turn on the burner, turn on all electric power to this appliance and
turn on the gas supply.
7. Press the “ON/OFF” key on the transmitter.
8. If the appliance will not operate, follow the instructions "TO TURN OFF
GAS TO APPLIANCE" and call your service technician or gas supplier.
Gas Supply
Closed (OFF)
Gas Supply
Open (ON)