Quadra-Fire QFP38-LP Indoor Fireplace User Manual


 
Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/0948
11
11
Shrouds
Chase top shrouds may be eld constructed where permitted by regional building codes.
WARNING! Risk of Fire! Shrouds must be constructed
as speci ed. Improper construction may overheat chase
top.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building of cials.
• The following eld constructed shroud designs have been tested for Hearth Technologies replace systems and termination
caps.
The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel.
The wire mesh is optional but recommended and must be .018 in. thick minimum, 1/2 in. mesh.
A. HHT Shrouds
You may install a shroud with this replace. See Section 17.D. for a list of UL Listed shrouds. Follow the instructions
included with these optional components
Min.
Base Dim.
Min.
Base Dim.
Min.
Top Dim.
Min.
Top Dim.
Figure 11.1 Open Top Shroud Dimensions
B. Field Constructed Shrouds
Open Top Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Min. Base Dims.
in 19 x 19
mm 483 x 483
Min. Top Dims.
in 16 x 16