Quadra-Fire QFP38-LP Indoor Fireplace User Manual


 
Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/0924
Fan Replacement & Maintenance
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, screwdriver.
Remove door front and xed glass assembly; refer to
Sections 14.K. and 14.L.
• Remove logs.
Bend right front log tab down.
Bend tab flat
Figure 3.2 Bend Down Tab
Remove two mounting screws from front burner.
Slide burner to the left, lift left side up and out.
Ste
p
1
Step 2
Step 3
Figure 3.3 Remove Burner
Remove the two screws holding the dashboard in place,
remove dashboard to access gas line and valve wires.
Figure 3.4 Remove Screws Holding Dashboard
Remove eight screws holding valve plate in place.
Lift the valve assembly up and out. Set aside.
Figure 3.5 Remove Screws From Valve Plate
Figure 3.6 Lift Up & Remove Valve Assembly
Shut off gas and unhook ex line from the valve.
Unplug wires from the valve.