Quadra-Fire 7100FP-BK-B Indoor Fireplace User Manual


 
September 7, 2007
433-1390D
Page 55
7100FP EPA Woodburning Fireplace
R
4. I don’t get enough/any heat. What can I do about it?
Diagnostic Question Possible Causes of Condition Solutions
How much wood is used for re? Insuf cient fuel Make larger res
How well seasoned is the wood? Condition of fuel Burn seasoned wood: (split, covered
on top minimum 6 months, preferably a
year) (about 20% moisture)
Did you install a blower? Snap disc may be faulty Replace snap disc
How much heat ouput do you expect? Unrealistic expectations
Heat output too low for square foot-
age
Replace appliance with one with greater
heat output
How are air controls set? Operational problems Follow manufacturer’s instructions
5. The wood burns too fast. What can I do?
Diagnostic Question Possible Causes of Condition Solutions
What is the condition of the wood? Extremely dry wood Mix in less seasoned wood after re
established
How are air controls set? Operational problems Follow manufacturer’s instructions
Fireplace won’t shut down. ACC Timer is not working properly Call quali ed Quadra-Fire dealer