September 7, 2007
433-1390D
Page 11
7100FP EPA Woodburning Fireplace
R
B. Clearances
Figure 11.1 Clearances to Combustible Materials
Fire Risk
• Comply with all minimum clearances to combustibles as specifi ed.
• Framing or fi nishing material used on the front of, or in front of, the
appliance closer than the minimums listed, must be constructed entirely
of non-combustible materials (i.e., steel studs, concrete board, etc.).
Failure to comply may cause fi re.
WARNING
2 in. (51 mm) min.
Attic
Insulation
Shield
Ceiling Firestop
(ceiling)
(
r
o
o
f)
(attic)
(ceiling)
Ceiling Firestop
Offset/Return with
hanger straps
Storm Collar
Roof Flashing
2 in. (51 mm) min.
2 in. min.
(51 mm)
Must have 2 in. (51 mm)
minimum clearance
to header
2 in. (51 mm) min.
2 in. (51 mm) min.
2 in. (51 mm) min.
2 in. (51 mm) min.
1 in. (25mm) to side of appliance
(except at nailing flanges where it is 1/2 in. [13 mm])
1/2 in. (
1
3 mm
)
to back
of applian
ce
0 in.
to floor
0 in. to level
of standoffs