and Welcome to the
Q
uadra-Fire Famil
y
!
Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Quadra-Fire appliance, you
have our assurance of commitment to quality, durability, and
performance.
This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world’s most
advanced technology to achieve the optimum operation
of our stoves, inserts and fi replaces. And yet we are old-
fashioned when it comes to craftsmanship. Each unit is
meticulously fabricated and gold and nickel surfaces are
hand-fi nished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection. From design, to fabrication, to shipping:
Our guarantee of quality is more than a word, it’s Quadra-
Fire tradition, and we proudly back this tradition with a Lim-
ited Lifetime Warranty.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.
With warm regards,
SAMPLE: CLEARANCE TO COMBUSTIBLES LABEL
LOCATION: on hang tag on right side of fi replace
Manufactured
Date
Serial Number
Model Name
Test Lab
& Report No.
Model:
Serial No / Numéro De Série
OMNI-Test Laboratories, Inc.
Report #061-S-41-2
LISTED FIREPLACE, SOLID FUEL TYPE, ALSO SUITABLE FOR MOBILE
HOME INSTALLATION. (UM) 84 HUD.
"For Use with SolidWood Fuel Only."
Install and use onlyin accordancewith manufacturer's installation,venting andoperatinginstructions.
Anyareaincorporatingwarm orcold air ducts shallbe enclosedin accordancewith the manufacturer's
installation instructions.
Contact Your Local Building Or Fire Officials Or Authority Having Jurisdiction About Restrictions,
Installation Inspection And Permits Required In Your Area.
WARNING - For Mobile Homes:
Do not install in a sleeping room. An outside combustion air inlet
must be provided and unrestricted while unit is inuse. The structural integrity ofthe mobile home floor,
ceiling and walls must be maintained. The fireplaceneeds to be properly grounded to the frame of the
mobile home.
Components required for installation: HTI SLSeries Pipe or Dura Plus System, Termination Cap, Hearth
Extension and required accessory ChimneyAir Kit Part CAK4A.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing.
Electrical Rating: 115 VAC <3.0 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on firebrick.
Do not overfire. If heater or chimney connector glows, you are overfiring.
Do not use a fireplace insert or other products not specified for use with this product.
WARNING -
THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GASLOG SET OR ANY LOGSET.
TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET OR ANY LOG SET
INTO FIREPLACE.
Mustprovideasource of airto preventair starvation fromcombustionwhichcouldresultofhigh levels
of carbon monoxide.
Replace glass only with 5mm ceramic available from your dealer.
Optional Fire Screen Part Mesh-EPA, may be used ONLY in
USA
Product covered by US Patents 4,766,876; 5, 113,843; 5,341,794
Patent pending
Chimney sections at any level require a 2” (51mm) minimum
air space clearance between the framing and chimney section.
Minimum Clearances To Combustible Material
WITHIN ENCLOSURE AREA
Appliance to backwall 1/2" (13mm)
Appliance to sidewall 1" (25mm)
Duct boots to framing 0" (0mm)
Top standoffs to header 0" (0mm")
EXPOSED SURFACES
Faceplate to sidewall 16" (406mm)
Remote outlet air grills to ceiling 12" (305mm)
MANTEL
Mantel from base of fireplace 60" (1524mm)
Maximum mantel depth 12" (305mm)
FLOOR PROTECTION
U.S. ENVIRONMENTAL PROTECTIONAGENCY - Certified to comply with July 1990 particulate emission standards.
2007 2008 2009 Jan Feb Mar Apr May June July Aug Sept Oct. Nov. Dec.
Made in U.S.A
DO NOT REMOVE THIS LABEL
433-1400
Mfg by:
Combustible flooring 20" (508mm) in front of and 8" (203mm) to
either side of the fuel opening must be insulated with
non-combustible floor protection with a minimum thickness of 1"
(25mm) and ("k" value = 0.43
).
In Canada: The hearthextensionmust be installedaccordingto
the installation instructions.
R
www.quadrafire.com
TESTEDTO:
UL 127, ULC-S610-M87
007
Tested and
Listed by
Beaverton
Oregon USA
C
US
t
Senior
___________________________
Alan Trusler
Vice President
Dealer Channel
___________________________
Dan Henry
Vice President
Advanced Technolgies
_________________________
Jason Olmstead
Vice President &
General Manager
___________________________
Steve Tate
Quadra-Fire
Brand Manager
Page 2
433-1390D
September 7, 2007
R
7100FP EPA Woodburning Fireplace