Quadra-Fire 7100FP-BK-B Indoor Fireplace User Manual


 
September 7, 2007
433-1390D
Page 21
7100FP EPA Woodburning Fireplace
R
A. Chimney Requirements
Vertical distances are measured from the base of the re-
place as shown in Figure 21.1.
To determine the chimney components needed to complete
your particular installation, follow the steps below:
Determine the total vertical height of the fireplace
installation. This dimension is measured from the base of
the replace assembly to the point where the smoke exits
the termination cap.
Subtract the effective height of the replace assembly from
the overall height of the replace installation
(measured
from the base of the fireplace to the bottom of the
termination cap, 13 ft. (4m).
Refer to Table 21.2 to determine what components must
be selected to complete the replace installation.
Determine the number of ceiling restops, stabilizers,
roof flashing, etc. required to complete the fireplace
installation.
6 ft (1.8 m) max.
unsupported
run
20 ft (6.10 m) max.
pipe between an
offset & return
Ceiling firestop
35 ft (10.7 m)
max. straight
unsupported
chimney height
14.5 ft (4.42 m) min. height/single offset-return
20 ft. (6.10 m) min. height/double offset-return
50 ft (15.24 m) max. height
6
f
t
(
1.83 m
)
max.
unsupported chimney
above roof
46 in.
(1168 mm)
to top of
standoffs
Figure 21.1 Chimney Requirements
Table 21.2
Fire Risk
Must maintain 2 in. (51 mm) air clearance
to insulation and other combustible
materials.
WARNING
HEIGHT OF CHIMNEY COMPONENTS in. mm
Chimney Stabilizer
SL3 4-3/4 121
Firestops Spacers
FS338 0 0
FS339 0 0
FS340 0 0
Offsets/Returns
SL315 (15º) 13-3/8 340
SL330 (30º) 15-1/2 394
Roof Flashing
RF370 0 0
RF371 0 0
Chimney Sections*
SL306 4-3/4 121
SL312 10-3/4 273
SL318 16-3/4 425
SL324 22-3/4 578
SL336 34-3/4 883
SL348 46-3/4 1187
* Dimensions re ect effective height.
Note: A maximum of two pairs of offsets and returns may
be used.
B. Chimney Termination Requirements
Minimum overall straight height 13 ft 3.96 m
Minimum height with single offset/
return
14.5 ft 4.42 m
Double offset/return minimum height 20 ft 6.1 m
Maximum height 50 ft 15.24 m
Maximum chimney length between an
offset and return
20 ft 6.1 m
Maximum distance between chimney
stabilizers
35 ft 10.67 m
Maximum unsupported chimney
length between the offset and return
6 ft 1.83 m
Maximum unsupported chimney
height above the replace
35 ft 10.67 m
Maximum unsupported chimney
above roof
6 ft 1.83 m
WARNING
Do NOT connect this unit to a chimney ue
servicing another appliance.
Do NOT connect to any air distribution duct or
system.
May allow ue gases to enter the house.
Asphyxiation Risk.