7100FP EPA Woodburning Fireplace
R
A. Blower Replacement
7
7
Accessories
Screwdriver Slot
Screws
Unplug wire
harness before
removing fan
Blower Cord Location
The 7100FP Fireplace comes standard equipped with two
blowers, installed at the factory with electric access on the
right side of fi replace (as you face it).
Figure 31.1 Accessing Blower Motor
Figure 31.2 Blower Motor
Removing the Blower
1. Unplug the wire harness.
2. Lift blower from locating pins and remove. Repeat for
second blower if necessary. See Figure 31.2.
3. Connect new blower wires to wire harness.
4. Before installing the blower, make sure the grommets
are tightly in place. Insert the right blower and place
over the 2 locating pins. Repeat for other blower. Figure
31.3.
Blower Replacement Instructions
1. Remove the brick from the bottom of the fi replace and 3
of the back vertical bricks.
2. Remove the 2 screws from the access panel in the fi re-
box fl oor. See Figure 31.1.
3. Pry up the access panel using the screwdriver slot and
completely remove the panel.
Figure 31.3 Installing Blowers
5. Re-install bottom panel or fi rebox access panel in
reverse order as described above.
6 Replace the brick that was removed.
7. Reconnect the power.
Shock Risk
Disconnect power by turning off circuit breaker
BEFORE servicing.
CAUTION