Quadra-Fire 7100FP-BK-B Indoor Fireplace User Manual


 
September 7, 2007
433-1390D
Page 37
7100FP EPA Woodburning Fireplace
R
6.
Remove 2 screws from timer mounting plate. Figure
37.1.
Timer Plate
Rotate assembly up and
out through access door
Arm must be in this position
when re-installing
Figure 37.1
Figure 37.2
Figure 37.3
8. Remove old air chamber cover. Place the cover under
the bottom of the rebox. Using a 7/16 wrench attach the
(2) 1/4-20 bolts as shown in Figure 37.4.
F
ire
b
o
x B
o
tto
m
Air Chamber Cover
Attach with 1/4-20 bolts
Figure 37.4
Figure 37.5
7. P
lace your hand into the access door in the oor of the
replace. Let the timer assembly and plate drop down
and rotate it up through the access door. You will be
looking at the back side of the assembly. Figures 37.2 &
37.3.
9. Insert the new timer assembly into the access door with
the back side towards you. Please note the correct pos-
tion of the linkage lower arm in Figure 37.3.
10.
After re-installing the timer assembly through the re-
box access door, re-attach the timer assembly to the
air chamber cover using a Phillips head screw driver.
Figure 37.5.
11. Attach the linkage upper arm to the lower linkage arm.
Figure 36.6 on page 36.