7100FP EPA Woodburning Fireplace
Slanted Roofs
Flat Roofs
Chimney must
extend 3 ft
(914 mm)
above the roof
Chimney must extend 2 ft (610 mm)
above any portion of the roof
within 10 ft (3048 mm) of the chimney
Chimney must
extend 3 ft
(914 mm)
above the roof
Chimney must extend 2 ft (610 mm)
above any portion of the roof
within 10 ft (3048 mm) of the chimney
Figure 26.1 Termination Requirements
A Gas Termination Wood or Fuel Oil Termination
B 6 in. (152 mm) min. 20 in. (508 mm) min.
Gas, Wood or Fuel
Oil Termination
8 ft
(2.44 m)
(min. for B-Vent)
20 in.
(508 mm)
(min. for direct vent)
to
Perpendicular
Wall
18 in.
(457 mm)
A
Gas
Termination
B
Termination Caps Staggered Height
Figure 26.2 Multiple Chimneys
6
6
Complete the Enclosure
A. Chimney Termination (2-10-03 Rule)
Chimney Termination Requirements (See Figures 26.1 and 26.2)
• Must have a cap approved and listed for this fi replace system
• Must not be located where it will become plugged by snow or other material
• Must terminate at least 3 ft (914 mm) above the roof and at least 2 ft (610 mm) above any portion of the roof within 10 ft
(3.05 m)
• Must be located away from trees or other structures