Quadra-Fire 7100FP-BK-B Indoor Fireplace User Manual


 
Page 40
433-1390D
September 7, 2007
R
7100FP EPA Woodburning Fireplace
Fascia
Outer Can
Flange
Ember Strip (Seal gap with
High temp, noncombustible
sealant able to withstand
300°)
Tile or
Marble
Minimum 1 in. (51mm)
Cement Board or equivalent,
(or two 1/2 in. pieces) and
"k" value = 0.49.
Minimum 20 in. (508mm) in front and
8 in. (203mm) on sides to fuel loading doors
Tile or
Marble
Combustible Floor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . .
Fascia
Outer
Can
Flange
Ember Strip (Seal gap
with high temp,
noncombustible sealant
able to withstand 300°)
Tile or Marble
Minimum 1 in. 51mm)
Cement Board or
equivalent, (or two
1/2 in. pieces) and "k"
value = 0.49.
Min 20 in. (508mm) in front and 8 in.
(203mm) on sides to fuel loading doors
Combustible
Floor
2 x 4
2 x 4
3/4 in.
(19mm)
Plywood
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fascia
Outer
Can
Flange
Ember Strip
(Seal gap with
noncombustible
sealant)
Tile or Marble
Minimum 1 in. (51mm)
Cement Board or
equivalent, (or two
1/2 in. pieces) and
"k" value = 0.49.
Min 20 in. (508mm) in front and 8 in.
(203mm) on sides to fuel loading doors
Combustible Floor
2 x 4
2 x 4
3/4 in.
(19mm)
Plywood
Figure 40.1 Fireplace and Hearth Extension Flush on the Floor.
Figure 40.2 Fireplace and Hearth Extension Flush on Floor but on Raised Platform
Figure 40.3 Raised Hearth Extension to Bottom of Fascia