-37-
■ Alarm Setup
1. Open the Alarm Setup window.
2. External Alarm
• Select ON or OFF for External Terminal Input, and
click the [SET] button.
ON: Receives alarm inputs via the ALARM IN termi-
nal.
OFF: Ignores alarm inputs via the ALARM IN termi-
nal.
Note: See SPECIFICATIONS for alarm input condi-
tions.
3. E-mail Notice Setup
Note: Sending E-mails will not be possible in an
environment where POP (Post Office Protocol)
authentication is required.
E-mail Notice:
ON:
Sends an E-mail when an alarm arises.
OFF: Does not send.
The default setting is OFF.
E-mail Server Address (IP Address/Host Name):
Input the IP address or host name of the mail
server. The host name can be input in up to 128
characters. When using DNS, input a text line
with "host name. domain name".
Sender E-mail Address: Input the administrator’s
address. The default setting is NW-camera.
Attach Image:
ON:
Attaches the alarmed picture to the E-mail.
OFF: Does not attach.
The default setting is OFF.
• Click the [SET & REBOOT] button.
Destination E-mail Address:
• Input a maximum of four addresses and click the
[SET & REBOOT] button.
Delete Destination E-mail Address:
• Select an unwanted address and click the [DEL]
button.
4. Recording Setup
Number of recorded images (frames)
before:
0 - 20
after: 1 - 20
Image Recording Rate (fps)
before:
1/10, 1/5, 1/3, 1/2, 1, 2, 3.3, 5.
after: 1/10, 1/5, 1/3, 1/2, 1, 2, 3.3, 5, 10.
The default setting is 1 for both before and after.
• Click the [SET & REBOOT] button.
5. Panasonic Protocol Setup
Panasonic Protocol
ON:
Applies the Panasonic Protocol.
OFF: Does not apply.
Destination Port
Input a destination port number. The port number is
exclusively assigned to this function, and any other
usage is not allowed.
Number of Retries
Available Times:
1-25
• Click the [SET] button.
Destination IP Address
• Input a maximum of eight IP address for
Panasonic Protocol destination and click the
[SET] button.
Delete Destination IP Address
• Select an unwanted IP address and click the
[DEL] button.
6. External Terminal Alarm Output Setup
Alarm output is supplied from the Alarm OUT con-
nector when the Alarm input terminal or VMD is acti-
vated.
Alarm Type
Pulse:
Holds active status during the specified
time width.
Latch: Holds active status until it is reset manu-
ally.
Pulse Width
• Select a number from 1-100 if you selected
Pulse.
The pulse width will be the selected number x
100 ms.