When the appliance is installed at elevations above 4,500ft, and in the absence of speci c recommendations from the
local authority having jurisdiction, the certi ed high altitude input rating shall be reduced at the rate of 4% for each ad-
ditional 1,000ft.
Change in ame appearance from "HI" to "LO" is more evident in natural gas than in propane.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certi ed kit is used.
GDS60 - This appliance is not approved for closet or recessed installations. It is approved for bathroom, bed-
room and bedsitting room installations. This appliance may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes. (Rear vent) This application requires
changing the main burner ori ce.
GS60 - This appliance is approved for bedroom and bed-sitting room installations.
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the
model, venting and gas type of the unit.
For rating plate location, see “INSTALLATION OVERVIEW” section.
2.4 RATING PLATE
MODEL CDVS600/GDS60 APPROVED FOR BEDROOM, BATHROOM & BEDSIT-
TING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF
INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH
SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED
STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD,
TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE
MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA
NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ,
EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE
ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR,
SECTION 3280. DANS LE CAS OU CETTE NORME D’ETATS-UNIS NE PEUT
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE
MESURES DE SECURITE CONTRE L’INCENDIE POUR LES INSTALLATIONS
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES,
ANSI/NFPA 501A.
AFUE: 64%
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20
FEET RESPECTIVELY FOR TOP VENTED UNITS AND 13 INCHES AND 20 FEET
RESPECTIVELY FOR REAR VENTED UNITS. LES LONGUEURS HORIZONTALES
MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT
POUR UN EVACUATION VERTICALE ET 13 POUCES ET 20 PIEDS RESPECTIVE-
MENT POUR UN EVACUATION HORIZONTALE.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON
VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS.
PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION
PROPRE A NAPOLEON. REFERER AU MANUEL D’INSTALLATION DE PROPRI-
ETAIRE POUR L’EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REIN-
STALLER ET RESCELLER L’EVENT APRES AVOIR ASSURE LE MAINTIEN DU
SYSTEME DE PRISE D’AIR.
CERTIFIED UNDER: CSA 2.33-2000, ANSI Z21.88-2000 VENTED GAS FIREPLACE HEATER AS A DIRECT VENT
AND CSA2.22-M98,ANSI Z21.50-1998 VENTED GAS FIREPLACE AS A B-VENT. HOMOLOGUE SELON LES
NORMES: CSA 2.33-2000, ANSI Z21.88-2000 FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION EN TANT
QU’UNE EVACUATION DIRECTE ET CSA2.22-M98,ANSI Z21.50-1998 FOYER AU GAZ AVEC EVACUATION
EN TANT QU’UN EVENT “B”.
WOLF STEEL LTD BARRIE, ON CANADA
MADE IN CANADA / FABRIQUE AU CANADA
W385-0459
MODEL CS600/GS60
APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A
COUCHER, & UN STUDIO. THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER KIT GS-150KT. CET APPAREIL DOIT ETRE
INSTALLE EN UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT.
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL
*WHEN VENTING OFF THE REAR OF THE UNIT AND TERMINATING HORIZONTALLY
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.
(LP)
PRESSION AU COLLECTEUR: 3.5” (GN) / 10” (PG) D’UNE COL-
ONNE DÉAU
MIN SUPPLY PRESSURE: 4.5” W.C. (NG) / 11” (LP)
PRESSION D’ALIMENTATION MIN: 4.5” (GN) / 11” (PG) D’UNE
COLONNE D’EAU
MAX. SUPPLY PRESSURE: 7” W.C. (NG) / 13” W.C. (LP)
PRESSION D’ALIMENTATION MAX: 7” (GN) / 13” (PG) D’UNE
COLONNE D’EAU
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULE-
MENT AVEC CETTE UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
SERIAL NUMBER
NO. DE SERIE
GDS/CDVS60
DIRECT VENT B-VENT
GDS60N GS60N
CDVS600N CDVS600N
TOP VENT REAR VENT
0-4500 0-4500 0-4500
35,000
*21,000 35,000
21,000
*12,000 21,000
24,500
*14,700
#35 #45 #35
ALTITUDE (FT/PI) ELEVATION
INPUT (BTU/H) ALIMENTATION
REDUCED INPUT (BTU/H) ALIMENTATION REDUITE
OUTPUT (BTU/H) RENDEMENT
ORIFACE
B-VENT DIRECT VENT
GS60P GDS60P
CS600P CDVS600P
REAR VENT TOP VENT
0-4500 0-4500 0-4500
31,500
*21,000 31,500
22,000
*13,000 22,000
*14,700 22,050
#53 #55 #53
AVERTISSEMENT: N’AJOUTEZ PAS A CET APPAREIL AUCUN
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR
LE FABRICANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL / DEGAGE-
MENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
A 6”
B 6”
C 2”
20” TO CEILING FROM STOVE TOP
1” TO DIRECT VENT AND B-VENT / L’EVACUATION DIRECTE &
L’EVACUATION B
6” TO C-VENT/ A L’EVACUATION C
20” ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING/CLASS: 115V 1.5AMP 60HZ
OPTIONALBLOWER KIT / ENSEMBLE DE
VENTILATEUR FACULTATIF: GS64-KT
MODEL NATURAL GAS/GAZ NATURAL
MODEL PROPANE/PROPANE MODÈLE