Napoleon Fireplaces GDS60N Indoor Fireplace User Manual


 
43
W415-0788 / A / 09.22.09
11.0 MAINTENANCE
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing. This appliance and its venting system should
be inspected before use and at least annually by a quali ed service person. The appliance area must be kept
clear and free of combustible materials, gasoline or other ammable vapours and liquids. The ow of combus-
tion and ventilation air must not be obstructed.
1. In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies.
2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by
vacuuming or brushing, at least once a year.
3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not
burning properly.
4. Check to see that the pilot ames are large enough to engulf the thermocouple and the thermopile on one leg
and reaches toward the burner on the other leg.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned
on. A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon® dealer/dis-
tributor.
7. Check that the door gasketing is not broken or missing. Replace if necessary.
MAINTENANCE
MAINTENANCE
MAINTENANCE
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
!
WARNING