Napoleon Fireplaces GDS60N Indoor Fireplace User Manual


 
6
W415-0788 / A / 09.22.09
4.1
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conform with local codes. Installation practices vary from region to region and it is important to know the
speci cs that apply to your area, for example in Massachusetts State:
This product must be installed by a licensed plumber or gas tter when installed within the commonwealth
of Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of a appliance
insert or gas log.
The appliance off valve must be a “T” handle gas cock.
• The exible connector must not be longer than 36 inches.
A Carbon Monoxide detector is required in all rooms containing gas red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
A
NSI Z223.1 and NFPA 54 in the United States.
A
s long as the required clearance to combustibles is
maintained, the most desirable and bene cial location for an appliance is in the center of a building, thereby
allowing the most ef cient use of the heat created. The location of windows, doors and the traf c ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a oor or roof joist.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Appliance
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
When the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
The appliance, when installed with a blower, must be electrically connected and grounded in accordance with
local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or
the ANSI/NFPA 70-1996 National Electrical Code in the United States. The blower power cord must be con-
nected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug.
2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
GDS600 GS600
NG LP NG LP
Altitude (FT) 0-4,500 0-4500 0-4500 0-4500
Max. Input (BTU/HR) 35,000 (Top vent)
21, 000 (Rear vent)
31,500 (Top vent)
16,380 (Rear vent)
35, 000 31,500
Max. Output (BTU/HR) 27,300 24,570 27,300 24,570
Max. Steady State
Ef ciency (w/the fan on)
78% 78% 78% 78%
Max. A.F.U.E. 72% 71% 72% 71%
Min. Inlet Gas Supply
Pressure
4.5" Water Column 11" Water Column 4.5" Water Column 11" Water Column
Max. Inlet Gas Supply
Pressure
7" Water Column 13" Water Column 7" Water Column 13" Water Column
Manifold Pressure (Un-
der Flow Conditions)
3.5" Water Column 10" Water Column 3.5" Water Column 10" Water Column