[Outdoor model : P144 ~ P192]
A Outdoor unit B 1st branch
C Indoor unit D Cap
E Outdoor Twinning Kit F Header
* The total length of A1 and A2 is less than 10 m [32 ft].
B
E
A
A2A1
A
B C D
e
a b c d
C
C
CCC
unit 2
A
unit 1
E
A
A2A1
A
unit 2
A
unit 1
B
a
b
c d e
C
D
CC
CC
F
Precautions for outdoor unit combinations
Refer to [Fig. 9.2.2] for the positioning of twinning pipes.
[Fig. 9.2.2]
<A>Make sure the pipes from the twinning pipe to the outdoor unit are sloped downwards (towards the twinning pipes).
A
C
F
<B>When the piping on the outdoor unit side (from the twinning pipe) exceeds 2 m [6 ft], ensure a trap (gas pipe only) within 2 m [6 ft].
Make sure the height of the trap is 200 mm [7-7/8 in] or more.
If there is no trap, oil can accumulate inside the pipe, causing a shortage of oil and may damage the compressor.
(Unit: m [ft])
F
C
2
[
6
]
B
C
F
A (Unit: mm [in])
Outdoor model
P72
P96
P144
P192
unit 1
-
-
P72
P96
unit 2
-
-
P72
P96
Liquid pipe
ø
12.7 [1/2] Brazed
ø
12.7 [1/2] Brazed
ø
15.88 [5/8] Brazed
ø
15.88 [5/8] Brazed
Gas pipe
ø19.05 [3/4] Brazed
ø22.2 [7/8] Brazed
ø
28.58 [1-1/8] Brazed
ø
28.58 [1-1/8] Brazed
Liquid pipe
-
-
ø
9.52 [3/8] Flare
ø
9.52 [3/8] Flare
Gas pipe
-
-
ø19.05 [3/4] Brazed
ø22.2 [7/8] Brazed
Liquid pipe
-
-
ø9.52 [3/8] Flare
ø9.52 [3/8] Flare
Gas pipe
-
-
ø19.05 [3/4] Brazed
ø22.2 [7/8] Brazed
Unit combination A A1 A2
a, b, c, d, e (Unit: mm [in])
Model number
06, 08, 12, 15, 18
24, 27, 30, 36, 48, 54
72
96
Liquid pipe
ø6.35 [1/4]
ø9.52 [3/8]
ø9.52 [3/8]
ø9.52 [3/8]
Gas pipe
ø12.7 [1/2]
ø15.88 [5/8]
ø19.05 [3/4]
ø22.2 [7/8]
Downstream unit model total
~ 72
73 ~ 144
145 ~ 234
The 1st branch of P144 ~ P234
Joint
CMY-Y102S-G2
CMY-Y102L-G2
CMY-Y202-G2
4-Branch header
(Downstream indoor
unit model total
<
=
72)
CMY-Y104-G
8-Branch header
(Downstream indoor
unit model total
<
=
144)
CMY-Y108-G
10-Branch header
(Downstream indoor
unit model total
<
=
234)
CMY-Y1010-G
Outdoor Twinning Kit
CMY-Y100VBK2
Outdoor model
P144 ~ P192
B, C, D (Unit: mm [in])
Total capacity of indoor units
~ 54
55 ~ 72
73 ~ 108
109 ~ 144
145 ~ 234
Liquid pipe
ø9.52 [3/8]
ø9.52 [3/8]
ø9.52 [3/8]
ø12.7 [1/2]
ø15.88 [5/8]
Gas pipe
ø15.88 [5/8]
ø19.05 [3/4]
ø22.2 [7/8]
ø28.58 [1-1/8]
ø28.58 [1-1/8]