<Outdoor unit operation monitor function>
Digital indicator LED3 displays 2 digit number or code to inform operation condition and the meaning of error code by
controlling DIP SW2 on outdoor controller.
SW2 setting
1
ON
23456
Display detail
Explanation for display
Unit
Operation indicator SW2 : Indicator change of self diagnosis
<Digital indicator LED3 working details>
(Be sure that 1 to 6 in the SW2 are set to OFF.)
(1) Display when the power supply is ON.
When the power supply is ON, blinking displays by turns.
Wait for 4 minutes at the longest.
(2) When the display lights (Normal operation)
1Operation mode display
1
ON
23456
(Initial setting)
SW2
1 second
interval
LED3
(Lighting)
Display Operation Model
The tens digit : Operation mode
The ones digit : Relay output
O
C
H
d
Display
0
1
2
3
4
5
6
7
8
A
Compressor
Warming-up
Compressor
4-way valve
Solenoid valve
(SV1, 2)
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF / FAN
COOLING / DRY
HEATING
DEFROSTING
2Display during error postponement
Postponement code is displayed when
compressor stops due to the work of
protection device.
Postponement code is displayed while
error is being postponed.
(3) When the display blinks
Inspection code is displayed when compressor stops due to the work of protection devices.
Display Contents to be inspected (When power is turned on)
F3
F5
F9
E8
E9
EA
Eb
EC
E0~E7
63L connector(red) is open.
63H connector(yellow) is open.
2 connectors (63H/63L) are open.
Branch box/outdoor communication error (Signal receiving error) (Outdoor unit)
Indoor/branch box communication error (Signal receiving error) (Branch box)
Branch box/outdoor communication error (Transmitting error) (Outdoor unit)
Indoor/branch box communication error (Transmitting error) (Branch box)
• Miswiring of indoor - branch box/branch box - outdoor unit connecting wire
• Too many indoor units/branch box are in the system.
Miswiring of indoor - branch box/branch box - outdoor unit connecting wire(converse wiring or disconnection)
Startup time over
Communication error except for outdoor unit
Display Inspection unit
0
1
Outdoor unit,
Branch box unit
Indoor unit
Display Contents to be inspected (During operation)
U2
U7
U1
UL
U6
UF
UH
UP
U3
U4
U5
U8
U9
PA
Discharge temperature fault
Low-discharge superheating fault, Erroneous connection of refrigerant pipes or the
connecting wires
High pressure fault (63H operates)
Low pressure fault (63L operates)
Abnormality of power modules
Compressor overcurrent shutoff (Start up locked)
Current sensor fault (P. B.)
Compressor overcurrent shutoff fault
Discharge pipe/compressor thermistor (TH4) open or short-circuit
Outdoor unit thermistors (TH3, TH6, TH7, and H8), 63HS, and branch box thermistors
open or short-circuit
HEATSINK temperature fault
Abnormality in outdoor fan motor
Voltage fault, current sensor fault (P.B.)
Forced compressor stop
(Overlap malfunction of drain pump in indoor unit and linear expansion valve in branch box.)