NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Step 1. Install the ceramic panels per the instructions provided in kit
(reference form #750182M).
Step 2. Place a mixture of volcanic stone and vermiculite around the
burner as shown in
Figure 43.
Step 3. Separate the glowing embers (rockwool) into pieces about the
size of a quarter
(see Figure 41). Keep the pieces fluffed, not
matted. Distribute these pieces over the burner as shown in
Figure 42. Do not use more than necessary. When properly
positioned, the Glowing Embers will cover approximately 75%
of the burner on natural gas. For propane gas, do not place
embers on main ports.
Note: Excessive use of embers may result in sooting or poor flame.
This appliance is provided with enough Glowing Embers for several
applications, do not feel compelled to use all that is in a new bag. For
best glowing effect, replace the ember material annually. Replacement
Glowing Embers are available (Catalog Number 88L53).
Step 4. Position the individual logs as shown in Figures 44 through 48.
Logs should be placed in the order shown.
Place logs 2 and 3
against the pins on the grate, NOT over them.
Proper log and twig placement is critical to encourage outstand
-
ing flame appearance and prevent sooting. When positioned
properly as shown, twigs will be positioned between flame
peaks and will not impinge any flames. Positioning is the same
for all colors of log sets.
Figure 41
Figure 42
Glowing Embers (Rockwool)
For Propane Gas Only, Do Not Place Embers On Main Ports
Figure 43 - (LSM45-2 Shown)
Mixture Of Volcanic Stone And Vermiculite
WARNING
DO NOT attempt to install the logs until the
appliance installation has been completed, the
gas line connected and tested for leaks and the
initial burner operation has been checked out.
The size and position of the log set was engi-
neered to give the appliance a safe, reliable
and attractive flame pattern. Any attempt to use
a different log set in the fireplace will void the
warranty and will result in incomplete combus-
tion, sooting, and poor flame quality.
Logs get very hot and will remain hot up to one
hour after gas supply is turned off. Handle only
when logs are cool. Turn off all electricity to
the appliance before you install grate, volcanic
stone, vermiculite, embers and logs.
This appliance is not designed to burn wood.
Any attempt to do so could cause irreparable
damage to the appliance and prove hazardous
to your safety.
If logs are not installed according to the log
installation instructions, flame impingement and
improper combustion could occur and result in soot
and/or excessive production of carbon monoxide
(CO), a colorless, odorless, toxic gas.
Step 8. LOG, VERMICULITE, VOLCANIC STONE AND GLOWING
EMBER PLACEMENT
REFERENCE - Firebox Accessories / Parts
Cat. No. Model Description
88L53 FGE Bag of Glowing Embers
80L42 FDVS Bag of Volcanic Stone
H6319 Bag of Vermiculite